首页> 外文期刊>European Physical Journal Plus >Real-time integration of control strategies for an isolated DFIG-based WECS
【24h】

Real-time integration of control strategies for an isolated DFIG-based WECS

机译:基于DFIG的WECs的实时整合控制策略

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

This paper deals with voltage and frequency control of a stand-alone wind energy conversion system (WECS) based on a double fed induction generator (DFIG) under wind speed and load variations. In this context, two kinds of linear and nonlinear control strategies, classical PI and backstepping, have been applied to the system in real time. A series of experiments have been conducted to evaluate and to compare dynamic performances of the proposed control approaches. Experiments on a 1.5Kw doubly fed induction machine in real time are carried out using dSpace DS1104 card based on the MATLAB/Simulink environment. Experimental results show the validity of implemented controllers and demonstrate the effectiveness, the precision and the rapidity of the backstepping control strategy compared with the PI controller.
机译:本文涉及基于风速和负载变化的双馈感应发生器(DFIG)的独立风能转换系统(WECS)的电压和频率控制。 在这种情况下,两种线性和非线性控制策略,古典PI和BackStepping已实时应用于系统。 已经进行了一系列实验来评估并比较所提出的控制方法的动态性能。 基于MATLAB / SIMULINK环境的DSPACE DS1104卡实时对1.5kW双馈入口机的实验。 实验结果表明,与PI控制器相比,实施控制器的有效性,展示了反向控制策略的有效性,精度和快速性。