首页> 外文期刊>European journal of anaesthesiology >Effectiveness of a visual noise warning system on noise levels in a surgical ICU A quality improvement programme
【24h】

Effectiveness of a visual noise warning system on noise levels in a surgical ICU A quality improvement programme

机译:视觉噪声警告系统对手术ICU中噪声水平的有效性A质量改进计划

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND The effects of noise are harmful to patients in the ICU environment, and the latter are particularly noisy places. High noise levels seem to be a factor in sleep disturbance, which can, in turn, result in increased morbidity. LOCAL PROBLEM High noise levels are a recognised problem in ICUs worldwide. OBJECTIVE(S) The goal was to estimate the effect of a visual noise-warning system on noise levels in a surgical ICU before and after its implementation. DESIGN A quality improvement initiative. SETTING A 12-bedded surgical ICU in a tertiary care university hospital. PATIENTS A total of 148 adult nonintubated and nonsedated patients completed the study, during a 6-week period. INTERVENTION Noise levels were continuously recorded using a Type II sound level meter for 6 weeks. The study was divided into three phases. The first 2 weeks, baseline noise levels were measured (phase I). In week 3 of the study, a visual noise warning system (SoundEar II) that changed colour depending on noise levels within the ICU was installed and implemented (phase II). The alarm system was set to light up green at levels below 55 dBA, orange at levels between 55 and 60 dBA and red at levels above 60 dBA. The device was switched off at the beginning of week 5 and the sound level meter continued recording noise levels for another 2 weeks (phase III). RESULTS Mean night-time noise level was 55.98 dBA in the preintervention phase, 54.14 dB during the intervention, and 54.98 dBA in the postintervention phase. Mean noise level was reduced statistically significantly by 1.35 dBA, and there was a sustained reduction of 0.86 dBA from the baseline noise level 2 weeks after SoundEar II was switched off. CONCLUSION Visual noise warning systems can be effective in achieving a reduction in noise levels in critical care units.
机译:背景技术噪声对ICU环境中的患者对患者有害,后者是特别嘈杂的地方。高噪音水平似乎是睡眠障碍的一个因素,这可以反过来导致发病率增加。本地问题高噪声水平是ICU全球的公认问题。目的是目标是估算视觉噪声警告系统在其实施之前和之后的手术ICU中的噪声水平的影响。设计质量改进倡议。在第三大学医院设定12层外科ICU。患者共有148名成人无因素和废除患者在6周内完成了该研究。使用II型声级仪表连续记录干预噪声水平6周。该研究分为三个阶段。前2周,测量基线噪声水平(I相)。在研究第3周,安装并实现了根据ICU内的噪声水平改变颜色的视觉噪声警告系统(SOUPSER II)(II期)。警报系统设置为在55 dBA低于55 dBA的级别下调绿色,橙色为55至60 dBa的水平,红色在60 dBA高于60 dBA。该装置在第5周的开始时关闭,声级仪表继续记录噪声水平2周(III阶段)。结果平均夜间噪声水平为55.98 dBa,在介入期间54.14 dB,介绍阶段54.98 dBa。平均噪声水平在统计学上显着降低1.35 dBa,并且在张力II后2周后,从基线噪声水平持续减少0.86 dBa。结论视觉噪声警告系统可以有效地实现严重护理单元中的噪声水平降低。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号