The purpose of this investigation was to conduct the failure analysis of 501 AISI furnace tubes places before distillation column in fractional distillation unit. The investigated furnace tubes were planned to work for ten years however after just two years of exploitation 30% of the material left. The observed corrosion process had the intense and complex character. The well-adhered shiny black deposits and deep, round pits were present after 2 years of exploitation. There is no direct explanation in the norms and standards for such abnormal intense corrosion taking place in described petroleum unit. The study based on the visual, optical and electron microscopy with chemical analysis via SEM and EDX of deposits was performed. Too high allowable operating temperature was identified as a main cause of such intense corrosion. The same measurements were performed for parallel working furnace tubes which was not subjected to premature degradation and were collected after 10 years of its normal operation in the installation. The performed measurements allowed us to determine that metal dusting as a the source of catastrophical corrosion. The work includes also an appropriate action in order to avoid the described corrosion threat.
机译:该研究的目的是在分数蒸馏单元中蒸馏塔前501 AISI炉管的故障分析。计划在仅仅两年的剥削之后,计划调查的炉子在工作中工作十年。剩下的30%的材料。观察到的腐蚀过程具有激烈和复杂的性格。经过2年的剥削后,存在良好的闪亮的黑色沉积物和深圆坑。在所述石油单元中发生这种异常强腐蚀的规范和标准中没有直接解释。进行了基于视觉,光学和电子显微镜通过SEM和EDX的沉积物进行化学分析的研究。允许太高的允许工作温度被鉴定为这种强烈腐蚀的主要原因。对并联工作炉管进行相同的测量,该管未受过早降解,并在安装中的正常运行10年后收集。所进行的测量允许我们确定金属粉尘作为灾难性腐蚀的来源。该工作还包括适当的行动,以避免所描述的腐蚀威胁。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号