The failure analysis of a cooling coil tube employed to extract the sensible heat of roasted zinc sulfide ore in a fluidised bed furnace type roasting unit was reported. The coils are prone to service degradation and subsequent failure due to the extreme operating conditions (920-960 degrees C). Severe corrosion attack and cracks were seen on the outer surface of the tube upon visual examination. The optical microscopy performed at the crack tip confirmed the deformation induced pearlitic banded structure. The corrosion products at the failure regions were rich in iron and zinc as revealed in the analysis by SEM with EDS. The galvanic corrosion between Fe and Zn is found to be the primary cause of the failure. It is hypothesized that the type of corrosion is possible with the zinc oxide acting as cathode with reference to the coil tube's outer surface. The selective corrosion resulted in the preferential corrosion attack and led to the premature failure of the tube. (C) 2017 Elsevier Ltd. All rights reserved.
机译:报道了用于提取流化床炉型焙烧单元中焙烧硫化锌矿石的清凉管管的冷却卷管的失效分析。由于极端操作条件(920-960℃),线圈容易发生使用劣化和随后的故障。在视觉检查时,在管外表面上看到严重的腐蚀攻击和裂缝。在裂纹尖端执行的光学显微镜确认了变形诱导的珠光体带状结构。故障区的腐蚀产品富含铁和锌,如SEM与EDS的分析中透露。发现Fe和Zn之间的电流腐蚀是失败的主要原因。假设氧化锌作为阴极的氧化锌是可以参考线圈管的外表面的腐蚀的类型。选择性腐蚀导致优先的腐蚀攻击并导致管的过早失效。 (c)2017 Elsevier Ltd.保留所有权利。