首页> 外文期刊>Engineering failure analysis >Analysis of degradation of a super-austenitic stainless steel for flue gas desulfurization system after a fire accident
【24h】

Analysis of degradation of a super-austenitic stainless steel for flue gas desulfurization system after a fire accident

机译:火灾事故后烟气脱硫系统超级奥氏体不锈钢降解分析

获取原文
获取原文并翻译 | 示例

摘要

A super-austenitic stainless steel (SASTS) which had been used for a fired flue gas desulfurization system was analyzed in terms of the microstructure, pitting resistance and hardness for the evaluation of degradation. The microstructural analysis showed that sigma phase, a metallic compound rich in Mo and Cr detrimental to corrosion resistance in SASTS, had precipitated all along the grain boundary of the alloy used for the reaction tank, while only isolated sigma phase was observed in the grain or at the grain boundary of the unused and the one from the mist eliminator. Several pits after an immersion test in a 60 deg C 6 percent FeCl_3 solution were developed only in the alloy from the reaction tank. Microscopic images around these pits indicated that the grain boundary had been selectively attacked. Hardness value was the highest for the alloy from the reaction tank. From these findings it was suggested that the degradation of the alloy used for the reaction tank was caused by the precipitation of sigma phase along the grain boundary due to an indirect heat affect from the fire accident.
机译:在用于评估降解评估的微观结构,蚀性抗性和硬度方面,分析了用于烧制烟道气脱硫系统的超级奥氏体不锈钢(SAST)。微观结构分析显示Sigma相,富含Mo的金属化合物和CR在Sast中的耐腐蚀性抗腐蚀性,沿着用于反应罐的合金的晶界沉淀,而在谷物中仅观察到分离的Sigma相或在未使用的晶界和雾中消除器中的晶界。在60℃的6%FECL_3溶液中浸渍试验后几个凹坑仅在来自反应箱的合金中开发。这些坑周围的微观图像表明晶界已经有选择性地攻击。硬度值对于来自反应箱的合金最高。从这些发现中,建议由于从火灾事故的间接热量影响,由沿晶界沿粒边缘沉淀而导致的合金的降解引起的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号