Estimation of instantaneous phase and frequency of harmonics-polluted single-phase grid voltage signal have been studied in this paper. The proposed approach uses a frequency adaptive Luenberger-sliding mode observer. Using Lyapunov stability theory, a frequency adaptation law has been proposed. The proposed frequency adaptive observer technique is robust against various perturbations faced in the practical settings, e.g., discontinuous jump of phase, frequency and amplitude. Global stability analysis of the closed-loop observer has been performed. Experimental results demonstrate the effectiveness of the proposed technique over a state-of-the-art technique proposed in the literature.
机译:本文研究了估计瞬时相位和谐波污染的单相网电压信号的频率。 所提出的方法使用频率自适应Luenberger-Sliding模式观察者。 使用Lyapunov稳定性理论,提出了频率适应法。 所提出的频率自适应观察者技术是针对在实际设置中面临的各种扰动的鲁棒,例如,不连续跳跃相位,频率和幅度。 已经执行了闭环观测器的全局稳定性分析。 实验结果表明,所提出的技术在文献中提出的最先进技术的有效性。