首页> 外文期刊>Echocardiography. >Assessment of right ventricular systolic function in heart transplant patients: Correlation between echocardiography and cardiac magnetic resonance imaging. Investigation of the accuracy and reliability of echocardiography
【24h】

Assessment of right ventricular systolic function in heart transplant patients: Correlation between echocardiography and cardiac magnetic resonance imaging. Investigation of the accuracy and reliability of echocardiography

机译:心脏移植患者右心室收缩功能评估:超声心动图和心脏磁共振成像的相关性。 考虑超声心动图的准确性和可靠性

获取原文
获取原文并翻译 | 示例
           

摘要

Background Right ventricular ( RV ) function has great impact on the survival of heart transplantation recipients; therefore, careful evaluation is of high clinical importance. However, there is no standard conventional echocardiographic parameter to assess RV systolic function. Herein, we evaluated the correlation between echocardiographic parameters of RV systolic function and ejection fraction assessed by cardiac magnetic resonance imaging ( MRI RVEF ) in heart transplantation recipients. Method and Results Forty‐three patients with at least 6‐month heart transplantation history were included in this study. Each patient had conventional echocardiography and cardiac MRI evaluation, followed by endomyocardial biopsy and right heart catheterization, which were performed in six hours. Echocardiographic parameters of RV systolic function, RV fractional area change ( RV FAC ), tricuspid annular plane systolic excursion ( TAPSE ), RV myocardial performance index, and RV global longitudinal strain, were compared with MRI RVEF ( P values were 0.001, 0.3, 0.9, and 0.4, respectively). RV FAC was the only parameter to strongly correlate with MRI RVEF ( r =0.747, P 0.001); and RV FAC 48.5% value had 90.5% sensitivity and 90.5% specificity to predict the pathologic reference value of MRI RVEF ≤50% ( AUC :0.96; 95% CI , 0.908–1.013). Conclusion To our knowledge, this is the first prospective study to evaluate the correlation between the echocardiographic parameters for RV systolic function and MRI RVEF in heart transplantation recipients. RV FAC is the only parameter to correlate well with MRI RVEF , and its routine use in the follow‐up of heart transplantation recipients should be considered.
机译:背景技术右心室(RV)功能对心脏移植受体的生存产生了很大影响;因此,仔细评估具有高临床重要性。但是,没有标准的常规超声心动图参数评估RV收缩功能。在此,我们评估了心脏移植受体中心脏磁共振成像(MRI RVEF)评估的RV收缩功能和喷射部分之间的超声心动图参数的相关性。该研究中包括43例心脏移植史的43例患者的方法和结果。每位患者具有常规超声心动图和心脏MRI评估,然后是子宫内膜活组织检查和右心导管插入,其在六个小时内进行。与MRI rveF(P值为P值,RV收缩函数的超声心动图(RV分数区域变化(RV FAC),三尖瓣环形平面收缩偏移(Tapse),RV心肌性能指标和RV全局纵向菌株(P值为0.001,& ; 0.3,& 0.9,分别为0.9。 RV FAC是与MRI RVEF强烈相关的唯一参数(R = 0.747,P <0.001); RV FAC 48.5%值具有90.5%的灵敏度和90.5%的特异性,以预测MRIRVEF≤50%的病理参考值(AUC:0.96; 95%CI,0.908-1.013)。结论据我们所知,这是第一个评估RV收缩功能与心脏移植接受者的RV收缩功能与MRI rvef之间的相关性的前瞻性研究。 RV FAC是与MRI RVEF相关的唯一参数,应考虑在心脏移植接受者随访中的常规使用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号