Purpose: Several studies have investigated effectiveness of fibrin spray or bipolar sealer to control peri-operative bleeding and reduce the need for blood transfusion, but a direct comparison between the two methods has not been previously performed. We conducted a prospective randomised trial, with standard electrocautery as a control group. Methods: In our investigation, 95 patients were randomised to one of three parallel groups receiving (1) 10 mL of topical fibrin spray before closure, (2) haemostasis with radiofrequency energy using a bipolar sealer, and (3) standard electrocautery. All patients and staff apart from the surgeons were blinded until data analysis was complete. Peri-operative blood loss has been calculated using a formula described by Ward and Gross (considering estimated patient blood volume, pre- and post-operative haemoglobin and haematocrit levels), with mention of eventual blood re-infusion or transfusion, at given intervals from surgery (6, 24, 48, 72 hours). Results: Mean blood loss was lower for both methods investigated, compared to the control group at every time interval considered, although differences were stronger for fibrin spray [Quixil]. Mean blood saving at the given intervals from surgery (6-24-48-72 hours) was respectively 96 ml, 129 ml, 296 ml, and 121 ml for bipolar sealer [Aquamantys] and 235 ml, 368 ml, 642 ml, and 490 ml for fibrin spray. These results are statistically significant (p = 0.05) for fibrin spray at every interval compared to control values, while a significance is detectable for bipolar sealer only at 48 hours after surgery. Conclusions: The fibrin spray group had the best performance in terms of blood loss, significantly reduced in comparison with the control group and bipolar sealer group. Blood loss reduction for the bipolar sealer was remarkable only at 48 hours, compared with the control group. Blood loss reduction for fibrin spray was significant at every time interval considered. Differences between the two treatments investigated and the control group narrowed slightly at 72 hours, as an expression of spontaneous homeostasis. Notable is the fact that blood volume saved with fibrin spray at 24 and 48 hours is comparable to the volume of at least one blood unit. A cost-effectiveness analysis should be considered in term of expense, biological risks (related to blood transfusion or human-derived products use) and bleeding-related complications.
机译:目的:几项研究已经研究了纤维蛋白喷雾或双极封口剂的有效性,以控制PERI-手术出血并减少对输血的需求,但之前尚未进行两种方法之间的直接比较。我们进行了一项前瞻性随机试验,标准电烙为对照组。方法:在我们的调查中,95名患者随机被随机分配到接受(1)10mL局部纤维蛋白喷雾剂之前的三个平行基团中的一种,(2)使用双极密封剂,(3)标准电疗法,用射频能量进行淋巴肿瘤。除了外科医生的所有患者和员工都被蒙蔽,直到数据分析完成。使用病房和总体(考虑估计患者血容量,术后血红蛋白和血细胞比容水平)描述的公式来计算PERI-手术损失,提及最终的血液再输注或输血。手术(6,24,48,72小时)。结果:两种方法的平均损伤较低,与每次考虑的对照组相比,每次考虑的对照组相比,虽然纤维蛋白喷雾[Quixil]差异较强。平均从手术的给定间隔(6-24-48-72小时)的血液储存分别为96ml,129ml,296ml和121ml,用于双极密封剂[海马羚]和235ml,368ml,642ml,和纤维蛋白喷雾490毫升。与对照值相比,这些结果在每个间隔时为纤维蛋白喷雾的统计学意义(p = 0.05),而双极密封剂在手术后48小时内,则可以检测到显着性。结论:纤维蛋白喷雾组在对照组和双极封口组比较方面具有最佳性能,显着降低。与对照组相比,双极封口剂的血液损失仅在48小时内显着。每次考虑纤维蛋白喷雾剂的血液损失都显着。研究的两种治疗与对照组之间的差异为72小时略微缩小,作为自发性稳态的表达。值得注意的是,在24和48小时的纤维蛋白喷雾中保存的血容量与至少一个血液单元的体积相当。应在费用,生物风险(与输血或人体衍生产品使用有关)和出血相关的并发症的成本效益分析。

著录项

  • 来源
    《International Orthopaedics》 |2013年第7期|共5页
  • 作者单位

    Orthopaedic and Traumatologic Department S. Spirito Hospital L.go Tevere in Sassia nr 1 00193;

    Orthopaedic and Traumatologic Department S. Spirito Hospital L.go Tevere in Sassia nr 1 00193;

    Orthopaedic and Traumatologic Department S. Spirito Hospital L.go Tevere in Sassia nr 1 00193;

    Orthopaedic and Traumatologic Department S. Spirito Hospital L.go Tevere in Sassia nr 1 00193;

    Orthopaedic and Traumatologic Department S. Spirito Hospital L.go Tevere in Sassia nr 1 00193;

    Orthopaedic and Traumatologic Department S. Spirito Hospital L.go Tevere in Sassia nr 1 00193;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 骨科学(运动系疾病、矫形外科学);
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号