Study of infiltration through sliding windows with respect to closing mechanisms and their locations in a building during winter season

机译:冬季建筑物中闭合机制及其地点渗透的研究

获取原文
获取原文并翻译 | 示例

摘要

Infiltration through windows accounts for a significant heat loss in buildings during winter, leading to the need to minimize uncontrolled air flow. Improvement of window air tightness is important for reducing heat loss by infiltration through windows. In this study, infiltration is measured for general sliding (GS), parallel sliding tilt (PST) and lift sliding (LS) windows according to ASTM E283, a standard for window infiltration measurement. Measured window infiltration data, pressure coefficients calculated with STAR-CCM+ and outdoor weather data of Seoul are used in CONTAM, a network based ventilation simulation program to estimate infiltration during winter season for three sliding window types and their locations in a building. The results show that infiltration is highest for east located general sliding type window, and lowest for west located parallel sliding tilt window. Monthly analysis shows that for an east located window, infiltration is highest during January and lowest during December.
机译:通过Windows渗透占冬季建筑物的显着热量损失,导致需要最大限度地减少不受控制的空气流量。窗户气密性的改善对于通过窗户渗透来降低热量损失是重要的。在该研究中,根据ASTM E283测量一般滑动(GS),平行滑动倾斜(PST)和提升滑动(LS)窗口的渗透,是窗渗透测量的标准。测量的窗口渗透数据,用STAR-CCM +和首尔的室外天气数据计算的压力系数在CONT中,基于网络的通风模拟程序,以估算冬季的渗透,用于三个滑动窗口类型及其在建筑物中的位置。结果表明,东部普通滑动型窗口最高,西部位于平行滑动倾斜窗口最低。每月分析表明,对于东方位于窗口,1月份的渗透率最高,12月期间最低。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号