Recently, considerable attention has been given to new environment-friendly refrigerant mixtures for applications such as heat pumps and air conditioners. This study presents flow boiling heat transfer characteristics of environment-friendly refrigerant mixture of R1234ze(E)/R600a (0.148/0.852, 0.194/0.806, 0.371/0.629, 0.623/0.377 and 0.797/0.203 by mole fraction) in a smooth horizontal tube with an inner diameter of 6?mm. The experiments were conducted at saturation pressures from 0.215 to 0.415?MPa, mass fluxes from 67 to 194?kg?m?2?s?1and heat fluxes from 10.6 to 74.8?kW?m?2. The influences of concentration, saturation pressure, mass flux and heat flux on heat transfer were analyzed and discussed. Furthermore, the experimental data were also compared with nine well-known flow boiling heat transfer correlations. The results indicated that correlation of Liu and Winterton (1991), which is the correlation for pure fluids, gives the best fit to the experimental data with a mean relative deviation of 18.2%. Finally, a new heat transfer correlation based on power-additive model was proposed and two suppression factorsSmixandFmixwere introduced into the new correlation by taking account of mass transfer resistance. The new correlation makes great progress in the prediction accuracy with a mean relative deviation of 6.4%.
机译:最近,已经对新的环保制冷剂混合物进行了相当大的关注,用于热泵和空调。本研究介绍了环形级联(E)/ R600A(0.148 / 0.852,0.194 / 0.85,0.371 / 0.629,0.371 / 0.629,0.623 / 0.377,0.623 / 0.377和0.797 / 0.377和0.797 / 0.203的流量沸腾的传热特性在光滑的水平管中内径为6Ωmm。实验以0.215至0.415β的饱和压力进行,从67-194的质量助熔剂进行,质量势次kg?m?2·s?1和热通量从10.6到74.8 kw?m?2。分析并讨论了浓度,饱和压力,质量通量和热通量对热传递的影响。此外,还将实验数据与九个众所周知的流沸腾传热相关性进行了比较。结果表明,Liu和Winterton(1991)的相关性,即纯净流体的相关性,给出了最适合的实验数据,其平均相对偏差为18.2%。最后,提出了一种基于电力 - 添加剂模型的新传热相关性,并通过考虑传质阻力来引入新相关性的两个抑制因子。新相关性在预测准确性方面取得了很大进展,其平均相对偏差为6.4%。

著录项

  • 来源
    《International Journal of Refrigeration》 |2018年第2018期|共12页
  • 作者单位

    Key Laboratory of Cryogenics Technical Institute of Physics and Chemistry Chinese Academy of Sciences;

    Key Laboratory of Cryogenics Technical Institute of Physics and Chemistry Chinese Academy of Sciences;

    Key Laboratory of Cryogenics Technical Institute of Physics and Chemistry Chinese Academy of Sciences;

    Key Laboratory of Cryogenics Technical Institute of Physics and Chemistry Chinese Academy of Sciences;

    Key Laboratory of Cryogenics Technical Institute of Physics and Chemistry Chinese Academy of Sciences;

    Key Laboratory of Cryogenics Technical Institute of Physics and Chemistry Chinese Academy of Sciences;

    Key Laboratory of Cryogenics Technical Institute of Physics and Chemistry Chinese Academy of Sciences;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 制冷理论;
  • 关键词

    R1234ze(E)/R600a; Azeotropic mixture; Flow boiling; New correlation; Heat transfer;

    机译:R1234ze(e)/ R600a;共沸混合物;流动沸腾;新相关;传热;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号