首页> 外文期刊>International Journal of Refrigeration >Linear adjustable inertance tubes for pulse tube cryocoolers
【24h】

Linear adjustable inertance tubes for pulse tube cryocoolers

机译:用于脉冲管冷冻机的线性可调节惯性管

获取原文
获取原文并翻译 | 示例
           

摘要

Inertance tube is coupled with Stirling Pulse Tube Cryocooler because its ability of varying the phase angle of pressure and mass flow thereby could potentially increase the performance of the pulse tube cryocooler. The discrepancy between the theoretically designed inertance tube and the installed one causes tons of work for the researchers to figure out the optimum dimensional parameters matching with the pulse tube cryocooler. This paper offers a substituted method to decrease the complications of determining the best match inertance tube for the specific cryocooler. A linear adjustable inertance tube is proposed to fulfill the requirement. The two section distributed component model with step transition and entrance effect resistance is built to anticipate the phase angle performance of the linear adjustable inertance tube. By a 16% length change, 12 degrees phase angle shift is captured both from the model prediction and the experimental measurement. Published by Elsevier Ltd.
机译:惰性管与斯特林脉冲管冷冻机联接,因为其改变压力和质量流量的相位角度的能力可能会增加脉冲管冷冻机的性能。 理论上设计的惯性管和安装的差异导致研究人员的吨作用,以弄清楚与脉冲管冷冻机匹配的最佳尺寸参数。 本文提供了一种替代方法,以减少确定特定冷冻机的最佳匹配惯性管的并发症。 提出了一种线性可调惯性管以满足要求。 采用阶梯过渡和入口效应电阻的两个分布式组件模型是为了预测线性可调惯性管的相角性能。 通过16%的长度变化,从模型预测和实验测量中捕获12度相位偏移。 elsevier有限公司出版