首页> 外文期刊>International Journal of Environmental Science and Technology >Study on arsenic removal in aqueous chloride solution with lead oxide
【24h】

Study on arsenic removal in aqueous chloride solution with lead oxide

机译:用氧化铅氯化物水溶液中除去砷的研究

获取原文
获取原文并翻译 | 示例
           

摘要

A new method to remove arsenic from aqueous chloride solution by using lead oxide was proposed, and the effects of the lead(II)/arsenic(V) molar ratio (n(Pb(II)):n(As(V))), initial pH of solution, initial concentrations of chloride ion (Cl-) and arsenic(V) on arsenic removal were investigated. The results showed that n(Pb(II)):n(As(V)), initial pH and initial Cl- concentration had great influence on arsenic removal. The suitable conditions of arsenic removal were initial pH of 1.8-2.4 and initial Cl- concentration of 0.52-2.00 g L-1 for 200 mg L-1 As(V) solution. Initial As(V) concentration had little influence on arsenic removal when the appropriate n(As(V)):nCl- was controlled in the solution at n(Pb(II)):n(As(V)) of 1.52. Based on these conditions, As(V) removal efficiency reached up to 99.99% and As(V) concentration decreased from 200 mg L-1 to less than 0.01 mg L-1 at initial pH of 1.8 with n(Pb(II)):n(As(V)) of 2.12. Various characterizations confirm that the formed precipitate was mimetite (Pb-5(AsO4)(3)Cl) and had better thermal stability within 500 degrees C. For the prevalent problem of lead dissolution by forming mimetite, Pb residual concentration reduced from 337.6 to 0.07 mg L-1 using sodium sulfide in the solution after arsenic removal. Therefore, lead oxide could be used as an effective reagent of arsenic removal to remove As(V) from aqueous chloride solution.
机译:提出了通过使用铅氧化物从氯化物溶液中除去砷的新方法,以及铅(II)/砷(V)摩尔比(N(Pb(II)):n(As(v))的影响) ,研究了溶液的初始pH,初始浓度的氯离子(Cl-)和砷(V)的砷去除。结果表明,N(Pb(II)):n(如(v)),初始pH和初始CL-浓度对砷的去除有很大影响。砷除去的合适条件为1.8-2.4的初始pH,初始Cl浓度为0.52-2.00g l-1,为200mg L-1作为(v)溶液。当适当的N(AS(v))在N(Pb(ii))中:1.52的溶液中控制时,初始(v)浓度对砷的去除几乎没有影响基于这些条件,如(v)去除效率高达99.99%,AS(v)浓度在1.8的初始pH下从200mg l-1降低至小于0.01mg l-1(pb(ii)) :n(如(v))为2.12。各种特征证实,形成的沉淀物是模拟物(PB-5(ASO 4)(3)CL),并且在500℃下具有更好的热稳定性。对于通过形成纤维石,Pb残留浓度从337.6减少到0.07的铅溶解的普遍存系问题。 Mg L-1在砷除去后溶液中使用硫化钠。因此,氧化铅可以用作砷除去的有效试剂,以从氯化物溶液中除去作为(v)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号