首页> 外文期刊>International archives of occupational and environmental health: Internationales Archiv fur Arbeits- und Umweltmedizin >An ergonomic field study to evaluate the effects of a rotatable handle piece on muscular stress and fatigue as well as subjective ratings of usability, wrist posture and precision during laparoscopic surgery: an explorative pilot study
【24h】

An ergonomic field study to evaluate the effects of a rotatable handle piece on muscular stress and fatigue as well as subjective ratings of usability, wrist posture and precision during laparoscopic surgery: an explorative pilot study

机译:一种符合人体工程学的田间研究,可评估可旋转手柄对腹腔镜手术中可用性,手腕姿势和精度的主观评级的影响:探索试验研究

获取原文
获取原文并翻译 | 示例
       

摘要

Purpose The interface between surgeon and the laparoscopic instrument is an important factor in biomechanical stress that may increase the risk of musculoskeletal complaints in surgeons. This article investigates the effect of a laparoscopic instrument with a rotatable handle piece (rot-HP) on muscular stress and fatigue during routine laparoscopic procedures (LP) as well as usability, wrist posture and working precision. Methods 40 LP (subtotal hysterectomies) performed by 11 surgeons were investigated. 20 LP were carried out with the rot-HP and 20 with a fixed (standard) laparoscopic handle piece instrument. Shoulder and arm muscle activity was monitored via surface electromyography (sEMG). The electrical activity (EA) and median power frequency (MPF) were used to determine muscular stress and fatigue. Usability, wrist posture, and working precision between handle piece conditions were assessed by a survey. Results Using the rot-HP did not reduce muscular stress. A tendency of muscular fatigue (increasing EA, decreasing MPF) occurred in the upper trapezius, middle deltoid and extensor digitorum muscles; however, no differences were found between handle pieces. Wrist posture was more comfortable using the rot-HP and working precision and usability tended to be preferred using the standard handle piece. Conclusions Although wrist posture seemed to be optimized by the rot-HP, no effect on muscular stress and fatigue was observed in routine LP (
机译:目的,外科医生与腹腔镜仪器之间的界面是生物力学应力的重要因素,可能会增加外科医生肌肉骨骼投诉的风险。本文研究了腹腔镜仪器在常规腹腔镜手术(LP)中的肌肉应力和疲劳以及可用性,手腕姿势和工作精度的肌肉应激和疲劳作用。方法研究了11种外科医生进行的40Lp(小特脑切除术)。用腐烂的HP和20进行20Lp,用固定(标准)腹腔镜手柄仪仪器。通过表面肌电图(SEMG)监测肩部和手臂肌肉活动。电气活动(EA)和中值功率频率(MPF)用于确定肌肉应力和疲劳。通过调查评估了手柄条件之间的可用性,手腕姿势和工作精度。使用ROT-HP的结果没有减少肌肉应力。在上梯形,中间三醇和伸肌位肌肉中发生肌肉疲劳(增加EA,降低MPF)的趋势;但是,手柄之间没有发现差异。使用标准手柄件使用ROT-HP和工作精度和可用性更加舒适,使用标准手柄倾向于优选。结论虽然腕部姿势似乎是通过腐肉优化的,但在常规LP(<β60≤min)中没有对肌肉应激和疲劳的影响。手腕姿势的优化可以在中期或长期手术中提供积极影响。然而,由于可以损害工作精度和可用性,与新仪器充分熟悉至关重要。

著录项

相似文献

  • 外文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号