首页> 外文期刊>Instruments and Experimental Techniques >Operation of Parallel-Connected DC-DC Converters
【24h】

Operation of Parallel-Connected DC-DC Converters

机译:并联连接的DC-DC转换器的操作

获取原文
获取原文并翻译 | 示例
           

摘要

The possibility of reducing the rated power of filter capacitors, i.e., the ratio of the product of the effective values of the voltage and current of a capacitor to the power of the DC-DC converter load, is shown. A DC-DC converter of the step-down type with a power of 40 W was used for this experimental study. A mathematical model was developed and a study of the change in the rated power for the converter components depending on the duty cycle and the number of cells of the converter was performed. The calculated and experimental dependences of the rated powers of the input and output filter capacitors and the effective value of the input current on the duty cycle for various numbers of used DC-DC converter cells are presented. The correspondence of the calculated and experimental values with an error of at most 10% has been obtained.
机译:示出了降低滤波器电容器的额定功率的可能性,即电容器的电压和电流电流的有效值的比率与DC-DC转换器负载的电力的比率。 使用40W的降压型的DC-DC转换器用于该实验研究。 开发了数学模型,并对转换器组件的额定功率的变化进行了研究,根据占空比和转换器的电池数量。 呈现了输入和输出滤波器电容器的额定功率的计算和实验依赖性以及各种数量使用的DC-DC转换器单元的占空比上的输入电流的有效值。 已经获得了计算的和实验值最多10%的实验值的对应关系。