首页> 外文期刊>Infection control and hospital epidemiology >Preliminary assessment of an automated surveillance system for infection control.
【24h】

Preliminary assessment of an automated surveillance system for infection control.

机译:感染控制自动监测系统的初步评价。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

BACKGROUND AND OBJECTIVE: Rapid identification and investigation of potential outbreaks is key to limiting transmission in the healthcare setting. Manual review of laboratory results remains a cumbersome, time-consuming task for infection control practitioners (ICPs). Computer-automated techniques have shown promise for improving the efficiency and accuracy of surveillance. We examined the use of automated control charts, provided by an automated surveillance system, for detection of potential outbreaks. SETTING: A 656-bed academic medical center. METHODS: We retrospectively reviewed 13 months (November 2001 through November 2002) of laboratory-patient data, comparing an automated surveillance application with standard infection control practices. We evaluated positive predictive value, sensitivity, and time required to investigate the alerts. An ICP created 75 control charts. A standardized case investigation form was developed to evaluate each alert for the likelihood of nosocomial transmission basedon temporal and spatial overlap and culture results. RESULTS: The 75 control charts were created in 75 minutes and 18 alerts fired above the 3-sigma level. These were independently reviewed by an ICP and associate hospital epidemiologist. The review process required an average of 20 minutes per alert and the kappa score between the reviewers was 0.82. Eleven of the 18 alerts were determined to be potential outbreaks, yielding a positive predictive value of 0.61. Routine surveillance identified 5 of these 11 alerts during this time period. CONCLUSION: Automated surveillance with user-definable control charts for cluster identification was more sensitive than routine methods and is capable of operating with high specificity and positive predictive value in a time-efficient manner.
机译:背景和目的:潜在爆发的快速识别和调查是限制医疗环境中传播的关键。手动审查实验室结果仍然是感染控制从业者(ICPS)的麻烦,耗时的任务。计算机自动化技术已经显示出提高监视的效率和准确性的承诺。我们检查了自动监控系统提供的自动控制图表的使用,以检测潜在的爆发。环境:一个656床学术医疗中心。方法:我们回顾性地审查了13个月(2001年11月至2002年11月)的实验室患者数据,比较了具有标准感染控制实践的自动监测应用。我们评估了调查警报所需的阳性预测值,敏感性和时间。 ICP创建了75个控制图。制定了标准化的案例调查表,以评估每种警报,以便为颞克朗透射的颞率和空间重叠和培养结果进行评估。结果:75个控制图在75分钟内创建,18个警报,在3秒形水平上方发射。这些由ICP和助理医院流行病学家独立审查。审查过程每次提醒平均每次提醒20分钟,审稿人之间的Kappa得分为0.82。 18个警报的11人被确定为潜在的爆发,产生阳性预测值为0.61。在此时间段内,常规监测确定了这11个警报中的5个。结论:对群集识别的用户可定义控制图的自动监测比常规方法更敏感,并且能够以较效的方式以高特异性和阳性预测值运行。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号