Background: Two-dimensional (2D) Look-Locker MRI technique can identify myocardial fibrosis, but cannot cover the whole left ventricle during a single scan. Purpose: To develop breath-hold three-dimensional (3D) Look-Locker MRI for the evaluation of postcontrast myocardial and blood T1 values and myocardial scarring in the left ventricle. Material and Methods: A phantom and 24 patients with myocardial diseases underwent gadoliniumenhanced 2D and 3D Look-Locker MRI using a 1.5-T unit. We compared the T1 value of the phantom and the values of the myocardium and blood in the patients between the two Look-Locker MRI sequences. In the patient study, the scan ordering of the two Look-Locker MRI was selected randomly. We also assessed the ability of the 3D imaging to detect myocardial scarring that was confirmed by late gadolinium enhancement MRI. Results: The phantom study showed a good agreement for the T1 value between 2D and 3D Look-Locker MRI. There were no significant differences in the myocardial T1 values after contrast between 2D and 3D Look-Locker MRI or in the T1 values between the two imaging slices on the 3D Look-Locker MRI (P > 0.10). A better agreement for the myocardial T1 values was found when the 3D Look-Locker imaging was performed first. The T1 values for blood were affected by the scan order (P < 0.05). The 3D Look-Locker MRI showed myocardial scarring with a shorter T1 value (290.4 ?? 62.7 ms) than those for unscarred myocardium (360.8 ?? 30.3 ms). Conclusion: Three-dimensional Look-Locker MRI may precisely estimate the postcontrast myocardial and blood T1 values for the entire left ventricle during a single scan.
机译:背景:二维(2D)Look-Locker MRI技术可以识别心肌纤维化,但在单次扫描期间无法覆盖整个左心室。目的:建立屏气三维(3D)Look-Locker MRI,以评估对比后的心肌和血液T1值以及左心室的心肌瘢痕形成。材料和方法:幻像和24例患有心肌疾病的患者使用1.5T装置进行了g增强的2D和3D Look-Locker MRI。我们在两个Look-Locker MRI序列之间比较了患者的体模的T1值以及患者的心肌和血液的值。在患者研究中,随机选择了两个Look-Locker MRI的扫描顺序。我们还评估了3D成像检测心肌瘢痕形成的能力,这一点已由晚期g增强MRI证实。结果:幻像研究显示2D和3D Look-Locker MRI的T1值具有很好的一致性。 2D和3D Look-Locker MRI对比后的心肌T1值或3D Look-Locker MRI上两个成像切片之间的T1值无显着差异(P> 0.10)。当首先执行3D Look-Locker成像时,发现对于心肌T1值有更好的一致性。血液的T1值受扫描顺序的影响(P <0.05)。 3D Look-Locker MRI显示,心肌瘢痕形成的T1值(290.4±62.7 ms)短于未疤痕的心肌(360.8±30.3 ms)。结论:三维Look-Locker MRI可以在一次扫描中精确估计整个左心室的对比后心肌和血液T1值。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号