X-ray dose delivered during a longitudinal micro-CT study has no adverse effect on cardiac and pulmonary tissue in C57BL/6 mice

机译:在纵向Micro-CT研究中提供的X射线剂量对C57BL / 6小鼠的心脏和肺组织无不利影响

获取原文
获取原文并翻译 | 示例

摘要

Background: Micro-computed tomography (micro-CT) offers numerous advantages for small animal imaging, including the ability to monitor the same animals throughout a longitudinal study. However, concerns are often raised regarding the effects of X-ray dose accumulated over the course of the experiment. Purpose: To scan C57BL/6 mice multiple times per week for 6 weeks, in order to determine the effect of the cumulative dose on pulmonary and cardiac tissue at the end of the study. Material and Methods: C57BL/6 male mice were split into two groups (irradiated group = 10, control group = 10). The irradiated group was scanned (80 kVp/50mA) three times weekly for 6 weeks, resulting in a weekly dose of 0.84 Gy, and a total study dose of 5.04 Gy. The control group was scanned on the final week. Scans from week 6 were reconstructed and the lungs and heart were analyzed. Results: Overall, there was no significant difference in lung volume or lung density or in left ventricular volume or ejection fraction between the control group and the irradiated group. Histological samples taken from excised lung and myocardial tissue also showed no evidence of inflammation or fibrosis in the irradiated group. Conclusion: This study demonstrated that a 5 Gy X-ray dose accumulated over 6 weeks during a longitudinal micro-CT study had no significant effects on the pulmonary and myocardial tissue of C57BL/6 mice. As a result, the many advantages of micro-CT imaging, including rapid acquisition of high-resolution, isotropic images in free-breathing mice, can be taken advantage of in longitudinal studies without concern for negative dose-related effects.
机译:背景:微型计算机断层扫描(micro-CT)为小型动物成像提供了许多优势,包括能够在整个纵向研究中监视相同动物的能力。但是,人们常常对在实验过程中积累的X射线剂量的影响提出关切。目的:每周对C57BL / 6小鼠进行多次扫描,共6周,以便确定研究结束时累积剂量对肺和心脏组织的影响。材料和方法:将C57BL / 6雄性小鼠分为两组(照射组= 10,对照组= 10)。每周对照射组进行三次扫描(80 kVp / 50mA),持续6周,每周剂量为0.84 Gy,总研究剂量为5.04 Gy。在最后一周对对照组进行扫描。重建第6周的扫描并分析肺和心脏。结果:总的来说,对照组和照射组之间的肺体积或肺密度或左心室体积或射血分数没有显着差异。从切除的肺和心肌组织中采集的组织学样本在照射组中也没有发现炎症或纤维化的迹象。结论:这项研究表明,在纵向微CT研究过程中,在6周内累积的5 Gy X射线剂量对C57BL / 6小鼠的肺和心肌组织无明显影响。结果,可以在纵向研究中利用微CT成像的许多优点,包括在自由呼吸的小鼠中快速获取高分辨率的各向同性图像,而无需担心剂量相关的负面影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号