首页> 外文期刊>Acta Radiologica >Evaluation of two different vacuum-assisted breast biopsy systems: Mammotome(R) system 11G/8G vs. ATEC(R) system 12G/9G.
【24h】

Evaluation of two different vacuum-assisted breast biopsy systems: Mammotome(R) system 11G/8G vs. ATEC(R) system 12G/9G.

机译:对两种不同的真空辅助乳腺活检系统的评估:Mammotome(R)系统11G / 8G与ATEC(R)系统12G / 9G。

获取原文
获取原文并翻译 | 示例
       

摘要

Breast cancer screening programs have been established worldwide and early detection of breast cancer has increased steadily. The most common way to confirm dignity of non-palpable and sonographically-occult suspicious findings on mammography is the stereotactically-guided vacuum-assisted breast biopsyTo compare two stereotactically guided vacuum-assisted breast biopsy systems measuring time effectiveness and quality of harvested material in clinical practice.One hundred and forty-six patients presenting with suspicious microcalcifications on mammography were included in the study. Biopsies were carried out with either the Mammotome(?) system (11-gauge and 8-gauge) or the ATEC(?) system (12-gauge and 9-gauge). Lesions with a diameter <15 mm on mammography were biopsied with 11-gauge or 12-gauge devices whereas lesions >15 mm were targeted with 8-gauge and 9-gauge. Mammotome(?) system 8-gauge device was used in 34 patients, the 11-gauge system in 37 patients. The ATEC(?) system 9-gauge system was used in 37 patients and 12-gauge in 38 patients. Time was taken, focusing on preparing the system, time of collecting the samples, preparing the samples, and cleaning the site. During the biopsies 24 samples were taken. The histologic quality of the tissue samples was judged by a pathologist in a blinded fashion according to a specimen grading classification concerning tissue fragmentation, artefacts, and the adequacy of the tissue for diagnosis.The median overall time for the Mammotome(?) system was 879 s (11-gauge) and 934 s (8-gauge) and for the ATEC(?) system 671 s (12-gauge) and 673 s (9-gauge). The ATEC(?) system displays a significantly shorter overall time for small and large biopsy devices (U-test, P < 0.001). Concerning the mean time difference of the overall time comparing small and large systems the ATEC(?) system was 267.6 s faster using the small and 244.8 s faster using the large system. Comparing the histologic quality of tissue samples the Mammotome(?) system shows significantly higher values for the large and the small system (Chi-square test, P < 0.001).Both biopsy systems meet all requirements for daily practice and confirm the diagnosis of suspicious microcalcifications. The ATEC(?) system was observed to be faster but this difference of about 250 s might not be relevant in daily practice. The Mammotome(?) system provides a better histologic quality of tissue samples.
机译:全世界已经建立了乳腺癌筛查计划,乳腺癌的早期发现稳步增长。确认乳房造影上不可触及和超声检查可疑发现的尊严的最常见方法是立体定向引导的真空辅助乳房活检比较两种立体定向引导的真空辅助乳房活检系统在临床实践中测量时间有效性和采集材料的质量该研究包括了146例在乳腺X射线摄影术中表现出可疑微钙化的患者。活检使用Mammotome(?)系统(11规和8规)或ATEC(?)系统(12规和9规)进行。乳腺X射线摄影术中直径小于15毫米的病变可用11或12规格的装置进行活检,而直径大于15毫米的病变则采用8规格和9规格的目标。 34例患者使用了Mammotome(?)系统的8号装置,37例患者使用了11号系统。 ATEC(?)系统9针系统用于37例患者,12针系统用于38例患者。花了时间,重点是准备系统,收集样品,准备样品和清洁现场的时间。在活检期间,采集了24个样品。组织样品的组织学质量由病理学家根据有关组织破碎,假象和组织是否足以进行诊断的标本分级分类以盲法进行判断.Mammotome(?)系统的总中位时间为879 s(11规格)和934 s(8规格),以及ATEC(?)系统的671 s(12规格)和673 s(9规格)。对于大小型活检设备,ATEC(?)系统显示的总时间明显缩短(U检验,P <0.001)。关于比较大型系统与小型系统的总时间的平均时间差,使用小型系统的ATEC(?)系统快267.6 s,使用大型系统的系统快244.8 s。比较组织样本的组织学质量,Mammotome(?)系统显示出较大和较小系统的值均显着较高(卡方检验,P <0.001)。两种活检系统均满足日常操作的所有要求并确认可疑诊断微钙化。观察到ATEC(?)系统速度更快,但是这种大约250 s的差异可能与日常实践无关。 Mammotome(?)系统可提供更好的组织样本组织学质量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号