首页> 外文期刊>Archives of orthopaedic and trauma surgery. >Fluid collection bags pose a threat for bacterial contamination in primary total hip arthroplasty: a prospective, internally controlled,non-blinded trial
【24h】

Fluid collection bags pose a threat for bacterial contamination in primary total hip arthroplasty: a prospective, internally controlled,non-blinded trial

机译:流体收集袋在初级总髋关节置换术中造成细菌污染的威胁:一项前瞻性,内部控制,非蒙蔽试验

获取原文
获取原文并翻译 | 示例
           

摘要

Introduction Surgical equipment, and especially the so-called 'splash basins' that are used intraoperatively, are a potential source of bacterial contamination in primary total hip arthroplasty (THA). With this risk in mind, many commercially available draping kits include plastic bags that can be used to collect fluid or to temporarily store instruments. Following this rationale, we hypothesised that first: the fluid collection bags are a potential reservoir of bacteria and second: there is a time dependency for bacterial contamination.Materials and methods After ethics approval, we investigated in a prospective, internally controlled, non-blinded trial 43 patients who received primary THA. At the beginning of the surgery, we took deep, representative, intracapsular tissue samples, which served as negative controls. At the end of surgery, tissue samples were taken from the bottom of the 'fluid collection bag' for microbiological analysis.Results All 86 control samples were negative. Out of the samples taken from the bags, a pathogen could be detected in four patients (9.3%). All pathogens were detected after a surgery time lasting longer than 90 min.Conclusion We were able to show that fluid collection bags are a potential reservoir for bacteria in THA when surgery time was greater than a 90-min threshold. Our data suggest that the risks from fluid collection bags outweigh the advantages of using them. Therefore, we recommend against the use of fluid collection bags intraoperatively in primary THA.
机译:引言手术设备,特别是术中使用的所谓的“飞溅盆地”,是初级总髋关节置换术(THA)中的细菌污染潜在来源。通过这种风险,许多市售的悬垂试剂盒包括可用于收集流体或临时存储仪器的塑料袋。在这一理由之后,我们假设第一:流体收集袋是细菌的潜在储层,第二次:有时依赖细菌污染。道德批准后,我们​​在伦理审批后的材料和方法,我们在潜在的内部控制,非蒙蔽后调查试验43患者接受初级THA。在手术开始时,我们深入,代表性,颅骨囊状组织样本,其用作阴性对照。在手术结束时,从“流体收集袋”的底部进行组织样品进行微生物学分析。结果所有86个对照样品都是阴性的。从袋中取出的样品中,可以在四个患者(9.3%)中检测到病原体。在持续时间超过90分钟的手术时间后检测到所有病原体。结论我们能够显示流体收集袋是在手术时间大于90分钟的阈值时为THA中的细菌的潜在储层。我们的数据表明,流体收集袋的风险超过了使用它们的优势。因此,我们建议在初学者中术中使用流体收集袋。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号