首页> 外文期刊>Analytical methods >Analysis of Cuban nickeliferous minerals by laser-induced breakdown spectroscopy (LIBS): non-conventional sample preparation of powder samples
【24h】

Analysis of Cuban nickeliferous minerals by laser-induced breakdown spectroscopy (LIBS): non-conventional sample preparation of powder samples

机译:激光诱导击穿光谱(LIBS)的古巴镍矿物分析:粉末样品的非常规样品制备

获取原文
获取原文并翻译 | 示例
           

摘要

In the present study, a new method to quantify Al, Cr, Fe, Mg, Mn, and Ni in nickeliferous minerals by laserinduced breakdown spectroscopy (LIBS) is proposed. Thirty-three mineral powder solid samples, previously analyzed by inductively coupled plasma optical emission spectroscopy (ICP OES), and two certified reference materials were used as reference samples for the calibration, and an innovative sample preparation was implemented and described. The use of Bi, Sc and Y as internal standards and the usefulness of other normalization modes were assessed in the normalization of the LIBS emission signals from the analytes. A slurry was made by mixing the solid mineral samples, grinding them into a fine powder, and using water in different proportions. Then, the mixture was homogenized and instantly weighed with a constant mass of a standard liquid solution of Y, which was preliminarily chosen as the internal standard among the three elements assessed, and a 10% (w v(-1))-polyvinyl-alcohol solution. After 2 h in an oven at 50 degrees C, the samples, which were immobilized in the polymer film, were subjected to LIBS analysis. The best sample dilution, emission line and normalization of the emission signal were selected for each analyte. The concentrations of the assessed analytes varied from 0.49 to 26.82% for Al, 0.40 to 2.21% for Cr, 6.8 to 52.93% for Fe, 0.41 to 20.53% for Mg, 0.11 to 1.50% for Mn and 0.23 to 3.02% for Ni. The standard error of validation (SEV) for the newly developed method was 1.34, 0.16, 6.08, 0.88, 0.09, and 0.35% for Al, Cr, Fe, Mg, Mn, and Ni, respectively.
机译:在本研究中,提出了一种通过激光诱导击穿光谱(LIB)来定量Al,Cr,Fe,Mg,Mn和Ni的新方法。先前通过电感耦合等离子体光发射光谱(ICP OES)分析的三十三种矿物粉末固体样品和两个认证的参考材料被用作校准的参考样品,并实施和描述了创新的样品制剂。在来自分析物的Libs发射信号的标准化中评估了BI,SC和Y作为内部标准和其他归一化模式的有用性。通过将固体矿物样品混合,将它们研磨成细粉末,并以不同比例使用水来制备浆液。然后,将混合物均匀化并立即用恒定的标准液体溶液纯度称重,这是在评估的三种元素中作为内标进行预先选择的,并且10%(WV(-1 )) - 聚乙烯 - 酒精溶液。在50摄氏度下在烘箱中2小时后,对在聚合物膜中固定的样品进行Libs分析。选择每个分析物的最佳样品稀释,排放线和发射信号的归一化。评估分析物的浓度为Al的0.49至26.82%,Fe,0.40至52.93%的0.40至2.21%,Mg为0.41至20.53%,Ni为0.11至1.50%,Ni为0.23至3.02%。新开发方法的验证标准误差(SEV)为Al,Cr,Fe,Mg,Mn和Ni的1.34,0.16,6.08,0.88,0.09和0.35%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号