...
首页> 外文期刊>American Journal of Physical Anthropology >Brief communication: Test of a method to identify double‐zonal osteon in polarized light microscopy
【24h】

Brief communication: Test of a method to identify double‐zonal osteon in polarized light microscopy

机译:简要沟通:测试偏振光显微镜中双地位膜的方法的测试

获取原文
获取原文并翻译 | 示例
           

摘要

Objectives: Double‐zonal osteons (DZ) have been of interest in paleopathological research because they might be linked to physiological pathology. DZ are thought to be evidence of arrested osteon formation with a brief but abrupt increase in mineralization of lamellae occurring during bone remodeling. Originally identified from microradiographs as hypermineralized rings, recent studies have identified DZ from linear polarized light microscopy (PLM). However, PLM does not guarantee the adequate detection of DZ since PLM captures bone birefringence and not hyper‐mineralization. Scanning electron microscopy with backscatter electrons (BSESEM) allows observation of DZ by detecting differences in mineralization. The purpose of this study is to investigate whether DZ, as identified by BSE‐SEM, can indeed be identified with PLM. Materials and methods: The sample consists of an archaeological collection of adult midshaft femurs (n = 30) from St. Matthew cemetery, Quebec City (1771–1860). DZ were identified and counted independently with PLM and BSE‐SEM for the same sections. Results from both methods were compared. Results: Chi‐square test shows that there was no significant difference between the two methods (p = 0.404). No significant bias was found on Bland‐Altman analysis and Cohen's kappa shows a substantial agreement between the two methods (Κ = 0.66). PLM shows a good accuracy (sensitivity 79%, specificity 99.4%) and reliability (Positive Predictive Value: 86.71%; Negative Predictive Value: 99.45%). Discussion: These findings indicate that the two methods are interchangeable. PLM, using our proposed protocol, is reliable to accurately identify DZ. We discuss how PLM and BSE‐SEM that measure different features of the bone tissue can converge on the identification of DZ.
机译:目的:双地区骨升(DZ)对古角病研究感兴趣,因为它们可能与生理病理学相关联。 DZ被认为是被捕患者形成的证据表明,在骨重塑期间薄片的矿化矿化的简短但突然增加。最初鉴定为微型造影作为高骨髓型环,最近的研究已经鉴定了直线偏振光显微镜(PLM)的DZ。然而,由于PLM捕获骨双折射而不是超矿化,PLM并不保证DZ的充分检测。用反向散射电子(Bsesem)扫描电子显微镜允许通过检测矿化的差异来观察DZ。本研究的目的是研究DZ是否通过BSE-SEM鉴定,确实可以用PLM识别。材料和方法:样品由魁北克市(1771-1860)的圣马修公墓的成人码头股骨(n = 30)的考古集合组成。用PLM和BSE-SEM独立识别和计算DZ,用于同一部分。比较了两种方法的结果。结果:Chi-Square测试表明,两种方法之间没有显着差异(P = 0.404)。在Bland-Altman分析中没有发现任何明显的偏见,Cohen的Kappa在两种方法之间显示了大量协议(κ= 0.66)。 PLM显示出良好的精度(灵敏度79%,特异性99.4%)和可靠性(阳性预测值:86.71%;负预测值:99.45%)。讨论:这些发现表明,这两种方法是可互换的。 PLM使用我们所提出的协议可靠地准确识别DZ。我们讨论如何测量骨组织的不同特征的PLM和BSE-SEM可以汇聚在DZ的识别上。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号