首页> 外文期刊>American journal of critical care >Developing the Synergy Model Patient Acuity Tool for Admission, Discharge, and Transfer
【24h】

Developing the Synergy Model Patient Acuity Tool for Admission, Discharge, and Transfer

机译:开发协同式模型患者敏锐性工具,用于入院,放电和转移

获取原文
获取原文并翻译 | 示例
       

摘要

Background The Admission DischargeTransfer-Synergy Model Acuity Tool (ADT-SMAT) was developed to quantify patient intervention intensity and patient response variability and to capture nurses' critical thinking. The tool is based on the American Association of Critical-Care Nurses Synergy Model for Patient Care. Objective To determine whether the ADT-SMAT is reliable and valid for predicting the level of care for admission, discharge, and transfer of critically ill patients. Methods Reliability was examined by using interrater reliability, intraclass coefficient, and effect size analyses to evaluate physiological variables and total calculated ADT-SMAT score in 246 patients. Content validity was determined in consultation with critical care nurses, and construct validity was examined by assessing the correlation between ADT-SMAT scores and other convergent and divergent constructs. Results The ADT-SMAT,showed strong reliability for measuring the physiological variables and total score, with an intraclass coefficient of 0.930.The value of Cohen d determining the effect size for each element of the ADT-SMAT was less than 0.20 for every element, indicating that substantial differences in scoring did not occur. The validity of the ADT-SMAT requires additional testing. Conclusions This is the first study attempting to correlate Synergy Model patient characteristics and acuity while integrating nurses critical decision-making process. With further testing, the ADT-SMAT could be a valuable tool to quantify and standardize patient characteristics in determining the appropriate level of care associated with admission, discharge, and transfer decisions.
机译:背景技术开发了通道放电转换器协同作用模型敏锐工具(ADT-SMAT)以量化患者干预强度和患者反应变异,并捕捉护士批判性思维。该工具是基于美国关键护理护理协会的患者护理协定模型。目的确定ADT-SMAT是否可靠,并且有效地用于预测批判性,放电和转移患者的护理水平。方法采用Interratiser可靠性,脑内系数和效果尺寸分析检查可靠性,以评估246名患者的生理变量和总计算的ADT-SMAT得分。内容有效期是以与关键护理护士进行协商确定的,通过评估ADT-SMAT分数与其他收敛和不同构建体之间的相关性检查构建有效性。结果ADT-SMAT,表现出测量生理变量和总分比的强度可靠性,其腹部系数为0.930.对于每个元件,COHEN D测定ADT-SMAT各元素的效果大小的值小于0.20,表明没有发生得分的大量差异。 ADT-SMAT的有效性需要额外的测试。结论这是第一次研究试图将协同态模型患者特征和敏锐性相关,同时整合护士关键决策过程。通过进一步测试,ADT-SMAT可以是有价值的工具,用于量化和标准化患者特征,以确定与入院,排放和转移决策相关的适当的护理水平。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号