首页> 外文期刊>Acta Radiologica >Removal of evidential motion-contaminated and poorly fitted image data improves IVIM diffusion MRI parameter scan–rescan reproducibility
【24h】

Removal of evidential motion-contaminated and poorly fitted image data improves IVIM diffusion MRI parameter scan–rescan reproducibility

机译:去除证据运动污染的和拟合不良的图像数据,提高了IVIM扩散MRI参数扫描重新扫描重复性

获取原文
获取原文并翻译 | 示例
       

摘要

Background It has been reported that intravoxel incoherent motion (IVIM) diffusion magnetic resonance imaging (MRI) scan–rescan reproducibility is unsatisfactory. Purpose To study IVIM MRI parameter reproducibility for liver parenchyma after the removal of motion-contaminated and/or poorly fitted image data. Material and Methods Eighteen healthy volunteers had liver scans twice in the same session to assess scan–rescan repeatability, and again in another session after an average interval of 13 days to assess reproducibility. Diffusion-weighted images were acquired with a 3-T scanner using respiratory-triggered echo-planar sequence and 16 b-values (0–800 s/mm~(2)). Measurement was performed on the right liver with segment-unconstrained least square fitting. Image series with evidential anatomical mismatch, apparent artifacts, and poorly fitted signal intensity vs. b-value curve were excluded. A minimum of three slices was deemed necessary for IVIM parameter estimation. Results With a total 54 examinations, six did not satisfy inclusion criteria, leading to a success rate of 89%, and 14 volunteers were finally included for the repeatability/reproducibility study. A total of 3–10 slices per examination (mean?=?5.3 slices, median?=?5 slices) were utilized for analysis. Using threshold b-value?=?80?s/mm~(2), the coefficient of variation and within-subject coefficient of variation for repeatability were 2.86% and 3.36% for D_(slow), 3.81% and 4.24% for perfusion fraction (PF), 18.16% and 24.88% for D_(fast); and those for reproducibility were 2.48% and 3.24% for D_(slow), 4.91% and 5.38% for PF, and 21.18% and 30.89% for D_(fast). Conclusion Removal of motion-contaminated and/or poorly fitted image data improves IVIM parameter reproducibility.
机译:背景技术据报道,透析运动(IVIM)扩散磁共振成像(MRI)扫描重复再现性是不令人满意的。目的在去除运动污染和/或拟合较差的图像数据后,研究IVIM MRI参数再现性的肝实质。材料和方法十八份健康的志愿者在同一会议中有两次肝脏扫描,以评估扫描rescan重复性,并且在13天的平均间隔之后再次在另一个会议中评估可重复性。使用呼吸触发回波平面序列的3-T扫描仪获得扩散加权图像,16b值(0-800 s / mm〜(2))。在右肝脏上进行测量,具有分段 - 无约束最小二乘配件。除了证据解剖不匹配,表观伪影和拟合不良信号强度与B值曲线的图像系列被排除在外。 IVIM参数估计需要至少三个切片。结果总共54次考试,六个不满足纳入标准,导致成功率为89%,最终载入可重复性/可重复性研究的14名志愿者。每次检查共3-10片(平均值?= 5.3切片,中位数?=?5切片)进行分析。使用阈值B值?=?80?S / mm〜(2),可重复性的变异系数和受试者内的变异系数为2.86%,对于灌注的3.81%和4.24%,可重复性为2.86%和3.36% D_(FAST)的级分(PF),18.16%和24.88%;对于PF的D_(慢速),4.91%和5.38%的D_(速度),21.18%和30.89%的重复性为2.48%和3.24%。(快速),21.18%和30.89%。结论去除运动污染和/或拟合较差的图像数据可提高IVIM参数再现性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号