首页> 外文期刊>Current opinion in lipidology >Cardiovascular epigenome-wide association studies: is epigenetics falling short?
【24h】

Cardiovascular epigenome-wide association studies: is epigenetics falling short?

机译:心血管外观一体化协会研究:表观遗传学缺少吗?

获取原文
获取原文并翻译 | 示例
       

摘要

BJUT-II VAD (Beijing University of Technology ventricular assist device II) is a novel left ventricular assist device. Because of the special connection between the pump and native heart, the hemodynamic effects of BJUT-II VAD on coronary artery are still unclear. Hence, numerical simulations have been conducted to clarify changes in hemodynamic effects of different support modes. A patient-specific left coronary arterial geometric model is reconstructed based on the computed tomography (CT) data. Three support modes, "constant speed mode," "co-pulse mode," and "counter pulse mode," are used in this study. The wall shear stress (WSS), wall shear stress gradient (WSSG), cycle-averaged wall shear stress (avWSS), oscillatory shear index (OSI), and the flow pattern are calculated to evaluate the hemodynamic states of coronary artery. The computational results demonstrate that the hemodynamic states of coronary artery are directly affected by the support modes. The co-pulse modes could achieve the highest blood perfusion (constant speed: 153 ml/min vs. co-pulse: 775 ml/min vs. counter pulse: 140 ml/min) and the highest avWSS (constant speed: 18.1 Pa vs. co-pulse: 42.6 Pa vs. counter pulse: 22.6 Pa). In addition, both the WSS and WSSG at the time of peak blood velocity under the constant speed mode are lower than those under other two support modes. In contrast, the counter pulse mode generates the highest OSI value (constant speed: 0.365 vs. co-pulse: 0.379 vs. counter pulse: 0.426). BJUT-II VAD under co-pulse mode may have benefits for improving coronary perfusion and preventing the development of atherosclerosis; however, the constant speed mode may have benefit for preventing the development of plaque vulnerability.
机译:Bjut-II Vad(北京技术大学室心辅助装置II)是一种新型左心室辅助装置。由于泵和本地心脏之间的特殊联系,Bjut-II VAD对冠状动脉的血液动力学效应仍然不清楚。因此,已经进行了数值模拟,以阐明不同支持模式的血液动力学效应的变化。基于计算机断层扫描(CT)数据重建患者特异性左冠状动脉几何模型。三种支持模式,“恒速模式,”“共脉冲模式”和“计数器脉冲模式”,在本研究中使用。壁剪切应力(WSS),壁剪切应力梯度(WSSG),循环平均壁剪切应力(AVWSS),振荡剪切指数(OSI),以及流动模式以评估冠状动脉的血液动力学状态。计算结果表明,冠状动脉的血液动力学状态直接受到支持模式的影响。共脉冲模式可以达到最高血液灌注(恒定速度:153ml / min,共脉冲:775ml / min与反脉冲:140ml / min)和最高的AVSS(恒定速度:18.1Pa vs 。共脉冲:42.6 PA与计数器脉冲:22.6 PA)。另外,恒定速度模式下峰值血液速度时的WSS和WSSG都低于其他两个支持模式下的WSS和WSSG。相反,计数器脉冲模式产生最高的OSI值(恒定速度:0.365与共脉冲:0.379 Vs.计数器脉冲:0.426)。共同脉冲模式下的Bjut-II VAD可能具有改善冠状动脉灌注和防止动脉粥样硬化的发育的益处;然而,恒定速度模式可能有利于防止斑块脆弱性的发展。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号