A large press uses a regenerative circuit to increase the closing speed of a ram. A pressure switch signals a PLC to close a logic slip-in cartridge valve so the ram can reach maximum tonnage. The press started having trouble developing enough tonnage when the logic valve did not close when Solenoid A was de-energized.