Concrete cooling towers experience various levels of concrete deterioration due to exposure to atmospheric conditions,cooling water chemistry,and various methods used to extend their service life.Despite being a critical asset,many cooling tower structures are inspected on an ad-hoc basis after problem conditions are discovered,often leading to more extensive repair conditions.This paper defines a standardized process and procedures for conducting inspections and condition assessments of concrete cooling towers.Inspection procedure recommendations are provided to aid a qualified team leader in carrying out the planning,observation,classification,and documentation of the physical condition of concrete cooling towers.Condition assessment procedures are then discussed to determine the need and priority of maintenance,repair,or rehabilitation actions based on information obtained from the structural inspection.The intent is to provide a systematic and proactive program for managing and maintaining cooling tower assets.
机译:混凝土冷却塔因暴露于大气条件,冷却水化学和用于扩展其使用寿命的各种方法而经历各种水平的混凝土劣化。分别是一种关键资产,在问题之后,许多冷却塔结构在临时基础上进行检查发现了条件,通常导致更广泛的维修条件。本文定义了用于对混凝土冷却塔进行检查和条件评估的标准化过程和程序。提供了展会的建议,以帮助合格的团队负责人进行规划,观察,分类,以及混凝土冷却塔身体状况的文献。然后讨论了监控程序,以确定基于从结构检查所获得的信息的维护,修理或康复行动的需求和优先级。目的是提供系统性和管理和MAI的主动计划奈良冷却塔资产。