首页> 外文期刊>Acta orthopaedica Scandinavica. >A new CT method for measuring cup orientation after total hip arthroplasty: a study of 10 patients.
【24h】

A new CT method for measuring cup orientation after total hip arthroplasty: a study of 10 patients.

机译:一种用于全髋关节置换术后测量杯方向的CT新方法:一项针对10位患者的研究。

获取原文
获取原文并翻译 | 示例
       

摘要

BACKGROUND: It is difficult to assess the orientation of the acetabular component on routine radiographs. We present a method for determining the spatial orientation of the acetabular component after total hip arthroplasty (THA) using computed tomography. PATIENTS AND METHODS: Two CT-scans, 10 min apart, were obtained from each of 10 patients after THA. Using locally developed software, two independent examiners measured the orientation of the acetabular component in relation to the pelvis. The measurements were repeated after one week. To be independent of the patient position during scanning, the method involved two steps. Firstly, a 3D volumetric image of the pelvis was brought into a standard pelvic orientation, then the orientation of the acetabular component was measured. The orientation of the acetabular component was expressed as operative anteversion and inclination relative to an internal pelvic reference coordinate system. To evaluate precision, we compared measurements across pairs of CT volumes between observers and trials. RESULTS: Mean absolute interobserver angle error was 2.3 degrees for anteversion (range 0-6.6 degrees), and 1.1 degrees for inclination (range 0-4.6 degrees). For interobserver measurements, the precision, defined as one standard deviation, was 2.9 degrees for anteversion, and 1.5 degrees for inclination. A Student's t-test showed that the overall differences between the examiners, trials, and cases were not significant. Data were normally distributed and were not dependent on examiner or trial. INTERPRETATION: We conclude that the implant angles of the acetabular component in relation to the pelvis could be detected repeatedly using CT, independently of patient positioning.
机译:背景:很难在常规X线片上评估髋臼组件的方向。我们提出一种使用计算机断层扫描技术确定全髋关节置换术(THA)后髋臼组件的空间方向的方法。病人和方法:THA术后每10例患者分别进行两次CT扫描,相距10分钟。使用本地开发的软件,两名独立的检查人员测量了髋臼组件相对于骨盆的方向。一周后重复测量。为了与扫描过程中的患者位置无关,该方法包括两个步骤。首先,使骨盆的3D体积图像进入标准的骨盆方向,然后测量髋臼组件的方向。髋臼组件的方向表示为相对于骨盆内部参考坐标系的手术前倾角和倾斜度。为了评估精度,我们比较了观察者和试验之间成对的CT体积测量值。结果:平均绝对观察者角度误差为前倾为2.3度(范围0-6.6度),倾斜度为1.1度(范围0-4.6度)。对于观察者之间的测量,定义为一个标准偏差的精度为前倾为2.9度,倾角为1.5度。一个学生的t检验表明,审查员,试验和案例之间的总体差异并不显着。数据呈正态分布,不依赖检查者或试验。解释:我们得出的结论是,可以使用CT反复检测髋臼组件相对于骨盆的植入角度,而与患者的位置无关。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号