首页> 外文期刊>Clinical otolaryngology: official journal of ENT-UK ; official journal of Netherlands Society for Oto-Rhino-Laryngology & Cervico-Facial Surgery >Validity and reliability of three‐dimensional costal cartilage imaging for donor‐site assessment and clinical application in microtia reconstruction patients: A prospective study of 22 cases
【24h】

Validity and reliability of three‐dimensional costal cartilage imaging for donor‐site assessment and clinical application in microtia reconstruction patients: A prospective study of 22 cases

机译:微辐射重建患者供体现场评估及临床应用的三维昂贵软骨成像的有效性和可靠性:22例前瞻性研究

获取原文
获取原文并翻译 | 示例
           

摘要

Abstract Objectives This study assesses the ability to reconstruct costal cartilage images by using three‐dimensional visualisation software (Mimics) based on semi‐automated segmentation algorithm and to investigate its reliability and validity with an anthropometric analysis. Design Observational prospective study. Setting Plastic surgery department of a tertiary hospital. Participants Twenty‐two microtia patients who underwent autologous ear reconstruction. Main outcome measures Preoperative thoracic computed tomography data were processed to Mimics software for three‐dimensional costal cartilage imaging. The length, width, thickness and volume of the 9th costal cartilages were calculated from these images and compared with the direct measurements (DM) obtained intraoperatively. Results The intra‐examiner reliability and inter‐examiner reliability were high in terms of all four measurements (intraclass correlation coefficients, ICC: 0.876‐0.984). There were no significant differences between image‐based anthropometry and DM in the linear measurements except for the volume ( P ??.05). The mean volume calculation error of Mimics was ?0.08?±?0.13?mL. No correlation was found between the anthropometric variables and the absolute errors ( P ??.05). Furthermore, Bland‐Altman plots were used to evaluate the agreement between the two methods. Conclusions Despite a very small error was found in volume calculation, Mimics software was accurate and reliable in linear calculation. Three‐dimensional costal cartilage imaging was found to be an efficient tool for morphological evaluation of costal cartilages. We believe that with the application of individualised cartilage models based on three‐dimensional printing, the use of customised ear framework carving will be practicable in surgical training.
机译:摘要目标本研究评估了通过基于半自动分割算法使用三维可视化软件(模拟)来重建肋骨软骨图像的能力,并通过人类测量分析来研究其可靠性和有效性。设计观察前瞻性研究。设定第三高级医院的整形外科。参与者接受了自体耳重建的二十二个微量疗促患者。主要结果测量术前胸部计算断层扫描数据被处理为模仿三维肋骨软骨成像的软件。第9肋骨软骨的长度,宽度,厚度和体积由这些图像计算,并与术中获得的直接测量(DM)进行比较。结果,根据所有四次测量,检查器内部可靠性和考试间可靠性很高(跨读数相关系数,ICC:0.876-0.984)。除了体积之外的线性测量中,基于图像的人体测量法和DM之间没有显着差异(p≤0.05)。模拟的平均体积计算误差是?0.08?±0.13?ml。在人体测量变量和绝对误差之间没有发现相关性(P?&Δ05)。此外,Bland-Altman Plots用于评估两种方法之间的协议。结论尽管在体积计算中发现了非常小的误差,但模拟软件在线性计算中准确可靠。发现三维肋骨软骨成像是一种有效的肋骨形态学评估工具。我们认为,随着基于三维印刷的个性化软骨模型,使用定制的耳框架雕刻将在外科训练中可行。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号