...
首页> 外文期刊>Clinical Radiology: Journal of the Royal College of Radiologists >Contribution of the amount of contrast media used in pulmonary CT angiography to assess the diagnostic value of CT venography; comparison of 100 and 150 ml of contrast media
【24h】

Contribution of the amount of contrast media used in pulmonary CT angiography to assess the diagnostic value of CT venography; comparison of 100 and 150 ml of contrast media

机译:肺CT血管造影中使用的造影剂量的贡献评估CT静脉造影的诊断价值; 比较100和150毫升造影剂

获取原文
获取原文并翻译 | 示例

摘要

Aim: To prospectively compare the vascular attenuation achieved with 100 ml iohexol (350 mg I/ml) 75% with that achieved with 150 ml iohexol (350 mg I/ml) 75% for computed tomography (CT) venography, which was performed after CT pulmonary angiography. Materials and methods: A total of 122 patients were included in the study. Group A, comprising 52 patients (mean age 64.8 years, mean body weight 70.8 kg) received 150 ml iohexol (350 mg I/ml) contrast media. Group B, comprising 70 patients (mean age 61.2 years, mean body weight 71.4 kg) received 100 ml iohexol (350 mg I/ml) contrast medium. Results: Venous opacification values measured at all levels were significantly higher in group A than those in group B (p < 0.001). In group B the mean HU values were between 87 and 115 and only three of the patients had HU values less than 60 at the level of femoral vein. Assuming a venous enhancement of 80 HU as the cut-off value for accurate diagnosis of deep venous thrombosis, 22.8% (16/70) in group B and 7.6% (4/52; p = 0.028) in group A had non-diagnostic CT venography of left femoral vein. Conclusion: One hundred millilitres of contrast medium with a concentration of 350 mg I/ml may produce sufficient enhancement, but 150 ml of contrast medium provides better accuracy for the diagnosis of deep venous thrombosis diagnosis. For better enhancement of lower extremity deep veins, the concentration of the contrast medium and the patient's body weight may also have significance.
机译:目的:要预先比较用100ml碘(350mg I / ml)75%实现的血管衰减,用150ml碘己酮(350mg I / ml)75%用于计算断层扫描(CT)静脉造影,其在后面进行CT肺血管造影。材料和方法:研究中共有122名患者。 A组,包含52名患者(平均64.8岁,平均体重70.8 kg)接受150ml碘氧基(350mg I / ml)造影剂。 B组,包含70名患者(平均61.2岁,平均体重71.4千克)接受100ml碘氧基(350mg I / ml)造影剂。结果:A组在所有含量测量的静脉制透明度值比B组(P <0.001)中的那些明显高。在B组中,平均HU值在87和115之间,只有三个患者在股静脉的水平下少于60的HU值。假设80 HU的静脉增强作为准确诊断深静脉血栓形成的截止值,B组中B组和7.6%(4/52; p = 0.028)的非诊断左股静脉的CT静脉静脉。结论:浓度为350mg I / ml浓度的一百毫升造影剂可能产生足够的增强,但150毫升造影剂为深静脉血栓形成诊断提供了更好的准确性。为了更好地增强下肢深静脉,造影剂的浓度和患者体重也可能具有重要性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号