Objective To evaluate in vitro the changes in implant surface topography and roughness of commercial implants after instrumentation with five decontamination protocols. Material and methods Seventy-two titanium implants with a sandblasted and acid-etched (SLA) surface were placed 5 mm supra-crestally. Five groups of twelve implants were instrumented with the following protocols: a metal scaler tip (SCAL), a thermoplastic scaler tip (PEEK), a round titanium brush (RBRU), a tufted brush with titanium bristles (TNBRU), and a glycine-based air-powder abrasive (GLYC). A sixth group with untreated implants was used as control. Scanning electron microscope and confocal laser scanning microscope were utilized to evaluate the changes in the implant surfaces. Results The SCAL caused pronounced macroscopic alterations and damage of the implant surface, the PEEK left remnants of the plastic tip in the implant surface, and both titanium brush groups flattened the thread profile, while minimal alterations were observed in the GLYC. When compared to the control group, the roughness parameters (Sa) in the buccal aspect increased in the thread area of SCAL, and a minor reduction was observed in the PEEK while in the other groups, these values remained unchanged. In the valley areas, however the RBRU, TNBRU, and GLYC experienced a significant reduction (smoothening) indicating different accessibility of the decontamination protocols to the thread and valley. Similarly, the buccal aspects had more pronounced changes than those in the palatal aspect. Conclusion Within the limitations of this in vitro investigation, the tested protocols induced different macroscopic alterations and surface roughness changes that varied in the thread and valley area.
机译:目的探讨五种去污方案仪器植入物植入物地形和粗糙度的体外变化。材料和方法具有喷砂和酸蚀刻(SLA)表面的72颗钛植入物置于5mm上嵴。有五组十二种植入物用以下方案进行了仪表:金属缩放器尖端(SCAL),热塑性缩放器尖端(PEEK),圆形钛刷(RBRU),具有钛刷毛(TNBRU)和甘氨酸的簇绒刷 - 基于气粉磨料(GLYC)。用未处理的植入物的第六组用作对照。扫描电子显微镜和共聚焦激光扫描显微镜用于评估植入表面的变化。结果标量引起了植入物表面的明显宏观改变和损伤,植入表面中的塑料尖端的左侧残余,两种钛刷组平均螺纹轮廓,而在GLYC中观察到最小的改变。与对照组相比,颊角方面中的粗糙度参数(SA)增加在SCAS的螺纹区域中,并且在其他组中观察到轻微的减少,这些值保持不变。然而,在谷地区,然而,RBRU,TNBRU和GLYC经历了显着的减少(平滑),表明涤纶和谷的去污方案的不同可达性。同样,颊面方面的变化比腭方面更加明显。结论在这种体外调查的局限质内,测试方案诱导了在螺纹和谷地区变化的不同宏观变化和表面粗糙度变化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号