首页> 外文期刊>Clinical nuclear medicine >Can carbonated lime drink intake prior to myocardial perfusion imaging with Tc-99m MIBI reduce the extracardiac activity that degrades the image quality and leads to fallacies in interpretation?
【24h】

Can carbonated lime drink intake prior to myocardial perfusion imaging with Tc-99m MIBI reduce the extracardiac activity that degrades the image quality and leads to fallacies in interpretation?

机译:碳酸石灰饮料是否在心肌灌注成像之前用TC-99M MIBI减少肢体活性,降低图像质量并导致解释中的谬误?

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND: During myocardial perfusion imaging with Tc-99m sestamibi, intestinal and hepatic radiotracer activity commonly interfere with visualization of the inferior wall of the myocardium leading to difficulties in interpretation. This study was undertaken to assess if carbonated lime drink ingestion prior to imaging prevents the said interference and improves the quality of images. MATERIALS AND METHODS: The study group comprised 33 consecutive patients including 26 males (age range: 30-80 years) and 7 females (42-62 years) who were referred for myocardial perfusion imaging. Of 33 patients, 21 (18 males, 3 females) were imaged at rest, 5 patients (3 males, 2 females) underwent physical stress, and 7 patients (5 males, 2 females) had pharmacological stress with adenosine. Five to 10 minutes after intravenous injection of 296 to 444 MBq (8-12 mCi) Tc-99m MIBI, anterior, and left anterior oblique (LAO) 45 degree planar views were acquired with a gamma camera using LEHR collimator. Each view was acquired for 100 seconds in a 256 x 256 matrix in all patients. Thereafter each patient was administered about 250 mL of a carbonated lime drink and repeat views were acquired within 5 minutes with the same parameters. Quantitative assessment of counts in the inferior wall of myocardium (M) to those in adjacent abdomen (A) was performed on both pre- and postintervention studies by drawing an ROI of about 50 +/- 5 pixels. M/A ratios were recorded for each patient in both the groups. The student t test was performed to evaluate the significance of difference between pre- and postintervention images. P < 0.05 was considered significant. All patients underwent myocardial perfusion single photon emission computed tomography. RESULTS: It was found that the inferior wall of the myocardium was better visualized, and there was no interference from gut or hepatic tracer activity in postintervention planar and single photon emission computed tomography reconstructed views as compared with preintervention images in all patients. The M/A ratio expressed as mean +/- SD was significantly higher in the postintervention group, viz. 2.19 +/- 0.71 in the anterior and 2.07 +/- 0.70 in the LAO45 views as compared with those of preintervention values of 1.50 +/- 0.59 in the anterior and 1.41 +/- 0.49 in the LAO 45 views, respectively (P < 0.001). CONCLUSION: We conclude that intake of carbonated lime drink is a simple and an effective technique to improve the image quality of the inferior wall of the myocardium on myocardial perfusion imaging with Tc-99m MIBI. This technique may also help in reducing the time interval between injection of radiotracer and imaging, which is otherwise delayed in routine practice.
机译:背景:在心肌灌注成像与TC-99M SestaMibi,肠和肝脏放射性游粉蛋白活动中通常干扰心肌下壁的可视化,导致解释中的困难。本研究进行了评估,如果在成像前摄取碳酸石灰饮料可防止所述干扰并提高图像质量。材料和方法:研究组连续33名患者,其中包括26名男性(年龄范围:30-80岁)和7名女性(42-62岁),被称为心肌灌注成像。在33例患者中,21例(18名男性,3名女性)在休息,5名患者(3名男性,2名女性)接受身体压力,7名患者(5名男性,2名女性)具有腺苷的药理学胁迫。静脉注射296至444 MBQ(8-12MCI)TC-99M MIBI,前卫和左前斜(LAO)45度平面斜视,使用LEONR Collimator进行伽马摄像机获得50度。在所有患者中,在256 x 256矩阵中获得每次视图100秒。此后,每位患者施用约250ml碳酸石灰饮料,并在5分钟内通过相同的参数在5分钟内获得重复视图。通过吸引约50 +/- 5像素的ROI,对腹膜(A)中的心肌(M)下壁(M)下壁(A)中的数量评估进行定量评估。在两组中的每位患者记录m /一种比率。进行学生T检验以评估预防和后期图像之间的差异的重要性。 P <0.05被认为是显着的。所有患者均接受心肌灌注单光子发射计算断层扫描。结果:发现心肌的劣质壁更好地可视化,并且与所有患者中的肠道平面的肠道或肝脏示踪活动没有干扰,与所有患者的预参选图像相比,单一光子发射计算断层摄影重建视图。在PostInteraction Group,VIZ中表达为平均值+/-SD的M / A比率显着高。 2.19 +/- 0.71在前卫中的2.07 +/- 0.70的视图中,与前部45次景观中的1.41 +/- 0.49的预领取值和1.41 +/- 0.49相比(P < 0.001)。结论:我们得出结论,碳酸石灰饮料的摄入是一种简单而有效的技术,可以提高心肌灌注与TC-99M MIBI的肌动态灌注成像的劣质壁的图像质量。该技术还可以有助于减少注射放射反射器和成像之间的时间间隔,这在常规实践中延迟。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号