The current standard for sterilization of potentially infected bone graft by gamma irradiation and thermal or chemical inactivation potentially deteriorates the biomechanical properties of the graft. We performed an in vitro experiment to evaluate the use of high hydrostatic pressure (HHP); which is widely used as a disinfection process in the food processing industry, to sterilize bone grafts. Four femoral heads were divided into five parts each, of which 16 were contaminated (in duplicate) with 10(5)-10(7) CFU/ml of Staphylococcus epidermidis, Bacillus cereus, or Pseudomonas aeruginosa or Candida albicans, respectively. Of each duplicate, one sample was untreated and stored similarly as the treated sample. The remaining four parts were included as sterile control and non-infected control. The 16 parts underwent HHP at the high-pressure value of 600 MPa. After HHP, serial dilutions were made and cultured on selective media and into enrichment media to recover low amounts of microorganism and spores. Three additional complete femoral heads were treated with 0, 300 and 600 MPa HHP respectively for histological evaluation. None of the negative-control bone fragments contained microorganisms. The measured colony counts in the positive-control samples correlated excellent with the expected colony count. None of the HHP treated bone fragments grew on culture plates or enrichment media. Histological examination of three untreated femoral heads showed that the bone structure remained unchanged after HHP. Sterilizing bone grafts by high hydrostatic pressure was successful and is a promising technique with the possible advantage of retaining biomechanical properties of bone tissue.
机译:目前通过γ辐射和热或化学灭活灭菌的潜在受感染的骨移植的标准可能会使移植物的生物力学性质劣化。我们进行了体外实验,以评估使用高静水压力(HHP);其中广泛用作食品加工行业的消毒过程,消毒骨移植物。将四个股骨头分成五个部分,其中16个污染(重复)污染(重复),分别具有10(5)-10(7)CFU / mL的葡萄球菌Epidermidis,芽孢杆菌或假单胞菌铜绿假单胞菌或念珠菌蛋白酶。每个复制,将一个样品未经处理并类似地储存,作为处理的样品。剩下的四个部分被包括为无菌控制和无感染对照。 16份在高压值为600 MPa的高压值下进行HHP。在HHP,在选择性培养基上进行系列稀释液,并培养富集培养基,以回收低量的微生物和孢子。分别为组织学评估分别用0,300和600MPa HHP治疗三个另外的完整股骨头。没有负对照骨片段含有微生物。测量的菌落计数在阳性对照样品中具有预期的菌落计数优异的相关性。 HHP治疗的骨碎片没有培养板或富集培养基。三个未经处理的股骨头的组织学检查表明,HHP后骨骼结构保持不变。通过高静压压力灭菌骨移植物是成功的,是一种有希望的技术,具有保持骨组织的生物力学性质的可能性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号