首页> 外文期刊>Catheterization and cardiovascular interventions: Official journal of the Society for Cardiac Angiography & Interventions >First experience of the usage of a GORE GORE CARDIOFORM CARDIOFORM S S eptal O O ccluder device for treatment of a significant residual commissural mitral regurgitation jet following a M M itra C C lip procedure
【24h】

First experience of the usage of a GORE GORE CARDIOFORM CARDIOFORM S S eptal O O ccluder device for treatment of a significant residual commissural mitral regurgitation jet following a M M itra C C lip procedure

机译:第一次经验使用GORE GORE CARDIOM VIRCOFMOR S S EPTAL O o CCCRUDER装置,用于治疗M米ITRA C唇手术后的显着残留的二尖瓣反流射流

获取原文
获取原文并翻译 | 示例
           

摘要

Abstract The MitraClip (Abbott Vascular, Santa Clara, CA) procedure has emerged as a safe and effective treatment option for treatment of selected patients with severe mitral regurgitation (MR) who are at high risk for surgery. Effective reduction of MR is important to ensure an optimal clinical outcome. We present here the first case report of a significant commissural leak after a MitraClip procedure treated with a GORE CARDIOFORM Septal Occluder device (WL Gore & Associates, Flagstaff, AZ). Case report: An 81‐year‐old male presented with symptomatic recurrent MR following a MitraClip procedure using two clips. After adding another clip, there was still a residual jet medially. We plugged the gap using 12‐mm AMPLATZER Muscular VSD Occluder device (St. Jude Medical, Minneapolis, MN). MR was reduced but hemolysis occurred. We retrieved the VSD Occluder device to improve hemolysis, but the MR jet worsened to severe, so we placed a 30‐mm GORE CARDIOFORM Septal Occluder device. The device was stable, the MR jet was reduced dramatically, and hemolysis was not observed. Materials of these devices are mesh fabric made from nitinol and polyester in a VSD Occluder device and expanded polytetrafluoroethylene in GORE CARDIOFORM Septal Occluder device. The difference between device materials affects flow pattern of residual jet and hemolysis. In conclusion, the patient's risk for hemolysis is potentially affected by the occluder or plug material. GORE CARDIOFORM is a feasible choice to reduce the risk of hemolysis in a selected patient.
机译:摘要米特拉德利普(雅培血管,圣克拉拉,加利福尼亚州的程序已成为一种安全有效的治疗选择,用于治疗具有高患者手术风险的严重二尖瓣再舒缓(MR)。对于确保最佳的临床结果,MR的有效减少是重要的。我们在这里介绍了用血清心脏调节装置(WL Gore& Associates,Flagstaff,AZ)处理的Mitraclip程序后,第一个案例报告。案例报告:使用两条夹子的MITRACLIP程序后,一名81岁男性呈现出症状复发MR。添加另一个夹子后,仍然有一个残留的喷射。我们使用12毫米放大器肌肉VSD封堵器设备(圣裘德医疗,明尼阿波利斯,MN)插上差距。 MR减少但发生溶血。我们检索了VSD封堵器装置以改善溶血,但射流发动机造成严重,所以我们放置了30毫米的血腥心脏型隔膜封堵器装置。该装置稳定,MR射流显着降低,未观察到溶血。这些器件的材料是由镍钛诺和VSD封堵器装置中的聚酯制成的网状织物,并在血型心脏型隔膜封堵器装置中膨胀的聚四氟乙烯。器件材料之间的差异影响残留射流和溶血的流动模式。总之,患者的溶血风险可能受封堵器或塞材料的影响。 Gore Cardioform是一种可行的选择,可降低选定患者溶血的风险。

著录项

相似文献

  • 外文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号