首页> 外文期刊>Catheterization and cardiovascular interventions: Official journal of the Society for Cardiac Angiography & Interventions >Transcatheter closure of large secundum atrial septal defects using the 40 mm Amplatzer septal occluder: Results of an international registry.
【24h】

Transcatheter closure of large secundum atrial septal defects using the 40 mm Amplatzer septal occluder: Results of an international registry.

机译:经截面闭合大Secundum间隔缺陷使用40 mm放大器隔间封堵器:国际登记处的结果。

获取原文
获取原文并翻译 | 示例
           

摘要

Little is known about the efficacy and safety of the 40 mm Amplatzer septal occluder (ASO). Thirty-three patients (22 female, 11 male) with a large secundum atrial septal defect (ASD) underwent attempted device closure using the 40 mm ASO at a median age of 40 years (range, 14-81 years) and median weight of 65 kg (range, 48-98 kg). The median size of the ASD measured on 2D transesophageal echocardiography (27 patients) or intracardiac echocardiography (6 patients) was 30.5 mm (range, 24-39 mm) and the median balloon-stretched diameter was 37.7 mm (range, 32-43.7 mm). The median Qp:Qs ratio was 3.2:1 (range, 1.4-6.2). The attempt was unsuccessful in five patients; two had device embolization and one had left atrial wall perforation due to the sheath; all three required emergent surgery. The attempt was successful in the 28 remaining patients, resulting in complete immediate closure in 14 and a trivial residual shunt in 14. Fluoroscopy time ranged from 8.6 to 37.8 min (median, 12.2 min). At 24-hr follow-up, 2D transthoracic echocardiography with color flow Doppler revealed complete closure in 23 patients, and 5 had a trivial residual shunt. There were no complications encountered in patients who received the device. On follow-up, all patients are doing well. We conclude that the 40 mm ASO is safe and effective in most patients with a large ASD up to a diameter of 39 mm. However, the use of this device requires careful attention as the procedure may be unsuccessful or the device may embolize. (c) 2005 Wiley-Liss, Inc.
机译:关于40 mm放大器隔膜封堵器(ASO)的功效和安全性知之甚少。三十三名患者(22例女性,11只男性),具有大的Secundum间隔缺损(ASD)经历了40毫米ASO在40岁(范围,14-81岁)和65岁的中位数的40毫米ASO的尝试装置闭合kg(范围,48-98 kg)。 ASD的中位数尺寸测量的2D经乳膏超声心动图(27名患者)或肠内超声心动图(6名患者)为30.5毫米(范围,24-39毫米),中位球囊拉伸直径为37.7毫米(范围,32-43.7mm )。中位QP:QS比率为3.2:1(范围,1.4-6.2)。尝试在五名患者中不成功;两个有器件栓塞,并且由于鞘,一个人左侧壁穿孔;所有三种所需的紧急手术。该尝试在28名患者中取得成功,导致14中完全立即闭合,14中的微不足道的残留分流。透视时间为8.6至37.8分钟(中位数,12.2分钟)。在24小时随访中,2D Transthoracic超声心动图与彩色流量多普勒显示出23例患者的完全闭合,5个具有琐碎的残余分流器。收到该设备的患者没有遇到的并发症。在随访中,所有患者都表现不错。我们得出结论,在大多数患者直径为39毫米的大多数患者中,40毫米ASO安全有效。但是,使用该设备需要仔细关注,因为程序可能是不成功或设备可以栓塞。 (c)2005 Wiley-Liss,Inc。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号