Objective: Optimisation of imaging protocols is essential to maximise the use of image-guided radiotherapy. This article evaluates the time for daily online imaging with TomoTherapy? (Accuray?, Sunnyvale, CA), separating mechanical scan acquisition from radiographer-led image matching, to estimate the time required for a clinical research study (VoxTox). Methods: Over 5 years, 18 533 treatments were recorded for 3 tumour sites of interest (prostate, head and neck and central nervous system). Data were collected for scan length, number of CT slices, slice thickness, scan acquisition time and image matching time. Results: The proportion of coarse thickness scans increased over time, with a move of making coarse scans as the default. There was a strong correlation between scan time and scan length. Scan acquisition requires 40 s of processing time. For coarse scans, each additional centimetre requires 8 s for acquisition. Image matching takes approximately 1.5 times as long, so each additional centimetre needs 20 s extra in total. Modest changes to the imaging protocol have minimal impact over the course of the day. Conclusion: This work quantified the effect of changes to clinical protocols required for research. The results have been found to be reassuring in the busy National Institutes of Health department. Advances in knowledge: This novel method of data collection and analysis provides evidence of the minimal impact of research on clinical turnover. Whilst the data relate specifically to TomoTherapy, some aspects may apply to other platforms in the future.
机译:目的:成像协议的优化对于最大化使用图像引导放射疗法至关重要。本文评估日常在线成像与Comotherapy的时间吗? (Scomay ?, Sunnyvale,CA),从放射性师LED图像匹配分离机械扫描采集,估计临床研究学习所需的时间(Voxtox)。方法:超过5年,记录了18个533种肿瘤感兴趣部位(前列腺,头部和颈部和中枢神经系统)的治疗。收集数据以进行扫描长度,CT片数,切片厚度,扫描采集时间和图像匹配时间。结果:粗厚度扫描的比例随着时间的推移而增加,移动粗扫描作为默认值。扫描时间与扫描长度之间存在强烈的相关性。扫描采集需要40秒的处理时间。对于粗扫描,每个额外的厘米需要8秒进行收购。图像匹配只需要大约1.5倍,因此每个额外的厘米总共需要20秒。对成像协议的适度更改在一天的过程中对其产生最小的影响。结论:该工作量化了研究所需的临床协议变化的影响。已发现结果是在繁忙的国家卫生部门安心。知识的进展:这种数据收集和分析的新方法提供了对临床营业额的最小影响的证据。虽然数据具体涉及Tomotherapy,但某些方面可能适用于未来的其他平台。

著录项

  • 来源
    《British Journal of Radiology》 |2013年第1032期|共1页
  • 作者单位

    Cancer Research UK VoxTox Research Group Department of Oncology University of Cambridge;

    Cancer Research UK VoxTox Research Group Department of Oncology University of Cambridge;

    Cancer Research UK VoxTox Research Group Department of Oncology University of Cambridge;

    Cancer Research UK VoxTox Research Group Department of Oncology University of Cambridge;

    Cancer Research UK VoxTox Research Group Department of Oncology University of Cambridge;

    Oncology Centre Addenbrooke's Hospital Cambridge United Kingdom;

    Cancer Research UK VoxTox Research Group Department of Oncology University of Cambridge;

    Cancer Research UK VoxTox Research Group Department of Oncology University of Cambridge;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 放射医学;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号