OBJECTIVE: To compare the efficiency of pneumatic lithotripsy with and without the Accordion antiretropulsion device (PercSys, Palo Alto, CA, USA). MATERIALS AND METHODS: The study comprised two in vitro experiments: in experiment 1, 10 trials were conducted using stone phantoms (6 x 6 x 10 mm), placed in a horizontal acrylic tube submerged in normal saline. Pneumatic lithotripsy was applied using a Swiss LithoClast (Boston Scientific Corporation, Natick, MA, USA). Each phantom was hit with repeated single firings of the LithoClast until it had travelled 20 cm (control group). The same experiment was then repeated with the Accordion antiretropulsion device positioned proximal to a new stone phantom. In experiment 2, stone phantoms (5 x 5 x 5 mm) were placed in a model ureter made of silicone and submerged in normal saline. Pneumatic lithotripsy was applied continuously on 10 stones for 20 s (200 strikes) without the Accordion device (control group) and on 10 stones with the Accordion device in place (experimental group). The distance of retropulsion was recorded. All stone phantoms were weighed before and after pneumatic lithotripsy. RESULTS: In both experiments the Accordion group had a significantly greater percentage weight loss than the control group (experiment 1; 11% vs 3%; experiment 2, 53% vs 16%, both P < 0.001). CONCLUSIONS: The Accordion device significantly increased the fragmentation efficiency in both in vitro models. Preventing retropulsion and increasing fragmentation efficiency has the potential to increase the success rate, decrease secondary procedures for migrated stones, and shorten operative times.
机译:目的:比较手风琴抗误术装置(Percsys,Palo Alto,Ca,USA)的气动性碎石术的效率。材料和方法:该研究包括两种体外实验:在实验1中,使用石模(6×6×10mm)进行10个试验,置于浸没在刚盐水中的水平丙烯酸管中。使用瑞士Lithoclast(波士顿科学公司,Natick,Ma,USA)应用气动碎石。每种幻影都被重复的单次射击次射击击中,直到它行驶了20厘米(对照组)。然后用定位在新的石幻影近端的手风琴抗逆脉动装置重复相同的实验。在实验2中,将石模(5×5×5mm)置于由硅氧烷制成的模型输尿管中并浸没在甘氨酸中。气动型碎石型在10块石头上连续施用20 s(200次尖头),没有手风琴装置(对照组)和10石,用手风琴装置到位(实验组)。记录了回归脉冲的距离。在气动性碎石术前后称重所有石幽灵。结果:在两种实验中,手风琴组的体重减轻百分比大于对照组(实验1; 11%vs 3%;实验2,53%Vs 16%,P <0.001)。结论:手风琴装置在体外模型中显着提高了碎裂效率。预防循环率和增加的碎裂效率有可能增加成功率,降低迁移的石头的二次程序,并缩短手术时间。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号