首页> 外文期刊>Academic radiology >Analysis of heart rate and heart rate variation during cardiac CT examinations.
【24h】

Analysis of heart rate and heart rate variation during cardiac CT examinations.

机译:心脏CT检查期间的心率和心率变化分析。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

RATIONALE AND OBJECTIVES: We sought to examine heart rate and heart rate variability during cardiac computed tomography (CT). MATERIALS AND METHODS: Ninety patients (59.0 +/- 13.5 years) underwent coronary CT angiography (CTA), with 52 patients also undergoing coronary artery calcium scanning (CAC). Forty-two patients with heart rate greater than 70 bpm were pretreated with oral beta-blockers (in five patients, use of beta-blocker was not known). Sixty-four patients were given sublingual nitroglycerin. Mean heart rate and percentage of beats outside a +/-5 bpm region about the mean were compared between baseline (free breathing), prescan hyperventilation, and scan acquisition (breath-hold). RESULTS: Mean scan acquisition time was 13.1 +/- 1.5 seconds for CAC scanning and 14.2 +/- 2.9 seconds for coronary CTA. Mean heart rate during scan acquisition was significantly lower than at baseline (CAC 58.2 +/- 8.5 bpm; CTA 59.2 +/- 8.8 bpm; baseline 62.8 +/- 8.9 bpm; P < .001). The percentage of beats outside a +/-5 bpm about the mean were not different between baseline and CTA scanning (3.5% versus 3.3%, P = .87). The injection of contrast had no significant effect on heart rate (58.2 bpm versus 59.2 bpm, P = .24) or percentage of beats outside a +/-5 bpm about the mean (3.0% versus 3.3%, P = .64). No significant difference was found between gender and age groups (P > .05). CONCLUSIONS: Breath-holding during cardiac CT scan acquisition significantly lowers the mean heart rate by approximately 4 bpm, but heart rate variability is the same or less compared with normal breathing.
机译:理由和目的:我们试图检查心脏计算机断层扫描(CT)期间的心率和心率变异性。材料与方法:90例患者(59.0 +/- 13.5岁)接受了冠状动脉CT血管造影(CTA),其中52例患者也接受了冠状动脉钙化扫描(CAC)。心率大于70 bpm的42例患者接受了口服β-受体阻滞剂的预处理(5例患者中,β受体阻滞剂的使用尚不清楚)。 64名患者接受舌下硝酸甘油治疗。在基线(自由呼吸),预扫描过度换气和扫描采集(屏气)之间比较了平均心率和大约+/- 5 bpm区域以外的平均心跳率。结果:CAC扫描的平均扫描采集时间为13.1 +/- 1.5秒,冠状动脉CTA的平均扫描采集时间为14.2 +/- 2.9秒。扫描获取期间的平均心率显着低于基线(CAC 58.2 +/- 8.5 bpm; CTA 59.2 +/- 8.8 bpm;基线62.8 +/- 8.9 bpm; P <.001)。在基线和CTA扫描之间,超出平均值的+/- 5 bpm之外的搏动百分比没有差异(3.5%对3.3%,P = 0.87)。注入对比剂对心率(58.2 bpm对59.2 bpm,P = 0.24)或+/- 5 bpm以外的平均心跳率(3.0%对3.3%,P = .64)没有显着影响。性别和年龄组之间无显着差异(P> .05)。结论:在心脏CT扫描中屏住呼吸会使平均心率显着降低约4 bpm,但与正常呼吸相比,心率变异性相同或更低。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号