首页> 外文期刊>Academic radiology >The Role of Ultrasonography in the Evaluation of Abdominal Fat: Analysis of Technical and Methodological Issues
【24h】

The Role of Ultrasonography in the Evaluation of Abdominal Fat: Analysis of Technical and Methodological Issues

机译:超声检查在评估腹部脂肪中的作用:技术和方法学问题分析

获取原文
获取原文并翻译 | 示例

摘要

Rationale and Objectives: Ultrasonography (US) is becoming popular for the assessment of adiposity, but no one has studied this tool in the light of its potential limitations. Our purpose was to investigate the impact of technical conditions on the evaluation of abdominal fat by US. Materials and Methods: Forty-five healthy males and 45 healthy females were consecutively enrolled in the study, randomly assigned to three groups equally distributed by sex, and examined accordingly to three technical points: fasting state (before and after meal [A]), breathing (expiration and inspiration [B]), and US equipment from different generations: 2003 and 1998 (C). Two blinded radiologists performed US in the these opposite conditions, acquiring five parameters representative of subcutaneous and visceral adiposity in two times. Student's t-test and Lin's correlation coefficient were used for statistical analysis to assess differences in the measures as well as in inter- and intra-observer agreements. Results: The maximum and the only statistically significant changes were observed for intra-abdominal fat thickness regarding fasting state and breathing (δ%=24.1±21.3 and δ%=9.2±20.4, respectively;. P<.0001). Reproducibility and repeatability, especially for visceral fat, were proved more stable in the following conditions: fasting state, expiration, and newer machine (2003). Conclusion: This article provides essential information and "range of confidence" for variations that can be expected from using differentconditions in the measurement of abdominal adiposity by US to be carefully addressed as well as considered by US users and by researchers involving this technique in the field of body composition.
机译:原理和目的:超声检查(美国)正变得越来越流行,用于评估肥胖,但没有人考虑到其潜在的局限性而对其进行研究。我们的目的是调查技术条件对美国腹部脂肪评估的影响。材料和方法:连续纳入研究的45位健康男性和45位健康女性,随机分为三组,按性别平均分配,并根据三个技术要点进行检查:空腹状态(饭前和饭后[A]),呼吸(呼气和吸气[B]),以及来自不同世代的美国设备:2003年和1998年(C)。两名不知情的放射科医生在这些相反的条件下进行了超声检查,两次获得了代表皮下和内脏脂肪的五个参数。学生的t检验和Lin的相关系数用于统计分析,以评估措施以及观察者之间和观察者内部协议之间的差异。结果:在禁食状态和呼吸方面,观察到腹内脂肪厚度的最大变化和唯一统计学上的显着变化(分别为δ%= 24.1±21.3和δ%= 9.2±20.4 ;. P <.0001)。再现性和重复性,尤其是内脏脂肪,在以下条件下被证明更稳定:禁食状态,有效期和更新的机器(2003年)。结论:本文提供了必要的信息和“置信范围”,这些差异是美国在腹部肥胖测量中使用不同条件时应谨慎对待并得到美国用户以及涉及该技术的研究人员所考虑的。身体成分。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号