首页> 外文期刊>Biosensors & Bioelectronics: The International Journal for the Professional Involved with Research, Technology and Applications of Biosensers and Related Devices >Imprinting of molecular recognition sites combined with pi-donor-acceptor interactions using bis-aniline-crosslinked Au-CdSe/ZnS nanoparticles array on electrodes: Development of electrochemiluminescence sensor for the ultrasensitive and selective detection of 2-methyl-4-chlorophenoxyacetic acid
【24h】

Imprinting of molecular recognition sites combined with pi-donor-acceptor interactions using bis-aniline-crosslinked Au-CdSe/ZnS nanoparticles array on electrodes: Development of electrochemiluminescence sensor for the ultrasensitive and selective detection of 2-methyl-4-chlorophenoxyacetic acid

机译:使用双苯胺交联的Au-CdSe / ZnS纳米粒子阵列在电极上结合pi-供体-受体相互作用的分子识别位点的印记:电化学发光传感器的开发,用于超灵敏和选择性地检测2-甲基-4-氯苯氧基乙酸

获取原文
获取原文并翻译 | 示例
           

摘要

A novel strategy is reported for the fabrication of bis-aniline-crosslinked Au nanoparticles (NPs)-CdSe/ZnS quantum dots (QDs) array composite by facil one-step co-electropolymerization of thioaniline-functionalized AuNPs and thioaniline-functionalized CdSe/ZnS QDs onto thioaniline-functionalized Au elctrodes (AuE). Stable and enhanced cathodic electrochemiluminescence (ECL) of CdSe/ZnS QDs is observed on the modified electrode in neutral solution, suggesting promising applications in ECL sensing. An advanced ECL sensor is explored for detection of 2-methyl-4-chlorophenoxyacetic acid (MCPA) which quenches the ECL signal through electron-transfer pathway. The sensitive determination of MCPA with limit of detection (LOD) of 2.2 nmol L-1 (S/N =3) is achieved by pi-donor-acceptor interactions between MCPA and the bis-aniline bridging units. Impressively, the imprinting of molecular recognition sites into the bis-aniline-crosslinked AuNPs-CdSe/ZnS QDs array yields a fiinctionalized electrode with an extremely sensitive response to MCPA in a linear range of 10 pmol L-1-50 mu mol L-1 with a LOD of 4.3 pmol L-1 (S/N=3). The proposed ECL sensor with high sensitivity, good selectivity, reproducibility and stability has been successfully applied for the determination of MCPA in real samples with satisfactory recoveries. In this study, ECL sensor combined the merits of QDs-ECL and molecularly imprinting technology is reported for the first time. The developed ECL sensor holds great promise for the fabrication of Qs-based ECL sensors with improved sensitivity and furthermore opens the door to wide applications of QDs-based ECL in food safety and environmental monitoring. (C) 2015 Elsevier B.V. All rights reserved.
机译:报道了通过硫代苯胺官能化的AuNPs和硫代苯胺官能化的CdSe / ZnS的一步式共电聚合制备双苯胺交联的金纳米颗粒(NPs)-CdSe / ZnS量子点(QDs)阵列复合材料的新策略将QD引入硫代苯胺官能化的Au电极(AuE)。在中性溶液中的修饰电极上观察到了CdSe / ZnS QDs的稳定和增强的阴极电化学发光(ECL),表明在ECL传感中具有广阔的应用前景。探索了一种先进的ECL传感器,用于检测2-甲基-4-氯苯氧基乙酸(MCPA),该化合物通过电子转移途径猝灭ECL信号。 MCPA与双苯胺桥联单元之间的pi-供体-受体相互作用实现了检测限(LOD)为2.2 nmol L-1(S / N = 3)的MCPA的灵敏测定。令人印象深刻的是,分子识别位点在双苯胺交联的AuNPs-CdSe / ZnS QDs阵列上的印记产生了一种功能化的电极,在10 pmol L-1-50μmolL-1的线性范围内,对MCPA的响应极为敏感LOD为4.3 pmol L-1(S / N = 3)。所提出的具有高灵敏度,良好的选择性,重现性和稳定性的ECL传感器已成功用于实际样品中MCPA的测定,回收率令人满意。在这项研究中,ECL传感器首次结合了QDs-ECL的优点和分子印迹技术。研发出的ECL传感器为制造基于Qs的ECL传感器提供了广阔的前景,该传感器具有更高的灵敏度,并且进一步为基于QDs的ECL在食品安全和环境监测中的广泛应用打开了大门。 (C)2015 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号