【24h】

Carbon fiber on-line detector for monitoring human blood serum reductive capacity. A complex technical solution

机译:碳纤维在线检测器,用于监测人血液血清还原能力。 复杂的技术解决方案

获取原文
获取原文并翻译 | 示例
           

摘要

The construction of a cylindrical carbon fiber on-line detector is presented, featuring a novel way of sealing the carbon fiber microelectrode, the design of an interchangeable carbon fiber microelectrode-based flow cell and its interface with data-acquisition electronics. The two-electrode setup was used, where the regeneration of the carbon fiber working electrode surface between analyses was performed using an electrochemical procedure, typically-1/+1 V potential cycling. The detector was incorporated into the flow injection analysis manifold and the applicability of the developed sensing platform tested for monitoring a hexacyanoferrate (II/III) redox probe and the oxidizable compounds trolox (6-hydroxy-2,5,7,8-tetramethylchroman-2-carboxylic acid), uric acid, and L-ascorbic acid, with dehydroascorbic acid as a negative control. Finally, the optimized procedure was utilized for the analysis of human blood serum reductive (antioxidant) capacity based on amperometric sensing and flow injection analysis at a flow rate of 10 mu l/min. Amperometric responses for blood serum samples were evaluated for standard deviation, whose average value was estimated to be +/- 0.3 nA (n = 20). The electrolytic efficiency of the detector was on the order of % units, e.g. 2% for trolox. The flow cell geometry and application of carbon fiber electrodes resulted in the absence of dead volumes and passivation phenomena, in contrast to conventional high-surface-area electrochemical cells. We suppose that the complex technical solution presented here could find a broad range of applications in the on-line monitoring of other reducing low-molecular bioactives and of the redox properties of various body fluids or clinical samples.
机译:提出了圆柱形碳纤维在线检测器的构造,具有密封碳纤维微电极的新方法,该碳纤维微电极的设计基于碳纤维微电极的流动电池及其与数据采集电子的界面的设计。使用两个电极设置,其中使用电化学程序进行分析之间的碳纤维工作电极表面的再生,通常是-1 / + 1V电位循环。将检测器掺入流动注射分析歧管中,并且测试的发达的传感平台用于监测六氰基甲酸酯(II / III)氧化还原探针和可氧化的化合物TroLox(6-羟基-2,5,7,8-四甲基溴 - 2-羧酸),尿酸和L-抗坏血酸,具有脱氢血脂酸作为阴性对照。最后,所述优化步骤,用于人血清的还原(抗氧化剂)容量基于电流计感测的分析,并在10亩升/分钟的流速流动注射分析。评估对血清样品的血清样品的浓度反应进行标准偏差,其平均值估计为+/- 0.3A(n = 20)。检测器的电解效率是大约%单位的顺序,例如单位。 Trolex 2%。与常规的高表面积电化学电池相比,流动池几何形状和碳纤维电极的施加导致没有死量和钝化现象。我们假设这里提出的复杂的技术解决方案可以在找到广泛的应用在线监测等减少低分子量的生物活性物和各种体液或临床样品的氧化还原特性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号