首页> 外文期刊>Journal of chromatography, A: Including electrophoresis and other separation methods >Critical evaluation of several techniques for the analysis of phthalates and terephthalates: Application to liquids used in electronic cigarettes
【24h】

Critical evaluation of several techniques for the analysis of phthalates and terephthalates: Application to liquids used in electronic cigarettes

机译:邻苯二甲酸盐和对苯二甲酸酯分析的几种技术的关键评价:电子烟中使用的液体应用

获取原文
获取原文并翻译 | 示例
           

摘要

This study describes several original methods that were developed with the goal of measuring phthalates and terephthalates. These methods include gas chromatography/mass spectrometry (GC/MS), GC/MS/MS, liquid chromatography with UV detection (LC/UV), LC/MS, and LC/MS/MS. The study compares the advantages and disadvantages of these methods and their applicability to measuring phthalates and terephthalates in the liquids used in electronic cigarettes (e-liquids). The analytes evaluated include eight phthalates and two terephthalates. The phthalates were diethyl, dibutyl, benzyl butyl, diphenyl, bis(2-ethylhexyl), di-n-octyl, diisononyl and diisodecyl. The terephthalates were dimethyl and bis(2-ethylhexyl). Intentionally, no cleanup or concentration step were used in the methods. The methods used two chromatographic standards, dimethyl phthalate-3,4,5,6-d(4), and di-(2-ethylhexyl) phthalate 3,4,5,6-d(4). All techniques were validated for selectivity/specificity, precision, sensitivity (evaluation of LOD and LOQ), as well as for repeatability and matrix interference. The GC methods were not adequate for the analysis of diphenyl, diisononyl, and diisodecyl phthalates which were not volatile enough to be seen in the conditions used for the GC separation. Also, alcohols should not be used as solvents for the injection of the sample in the GC system to avoid transesterification in the hot injection port. The single quadrupole MS detection in GC offers sensitivities around 1 mu g/mL in the e-liquid and was not sensitive enough for the analysis of trace phthalates and terephthalates. Compared to all evaluated methods, the MS/MS detection in GC offered the best sensitivity (below 10 ng/mL in the e-liquid). The LC is adequate for the separation of all the evaluated analytes. However, the UV detection in LC does not offer good sensitivity compared to all the other techniques. The MS detection in LC provides poor sensitivity for terephthalates, but better than the UV for the rest
机译:本研究描述了几种具有测量邻苯二甲酸酯和对苯二甲酸酯的目标的原始方法。这些方法包括气相色谱/质谱(GC / MS),GC / MS / MS,液相色谱,具有UV检测(LC / UV),LC / MS和LC / MS / MS。该研究比较了这些方法的优缺点及其对测量电子香烟(E-液体)中使用的液体中的邻苯二甲酸盐和对苯二甲酸酯的优点和缺点。评价的分析物包括八个邻苯二甲酸盐和两种对苯二甲酸盐。邻苯二甲酸酯是二乙基,二丁基,苄基,二苯基,双(2-乙基己基),二 - 正辛基,二硅烷基和二硅氧基。对苯二甲酸酯是二甲基和双(2-乙基己基)。有意地,在该方法中没有使用清理或浓缩步骤。该方法使用了两种色谱标准,邻苯二甲酸酯-3,4,5,6-D(4),和二 - (2-乙基己基)邻苯二甲酸酯3,4,5,6-D(4)。验证所有技术,用于选择性/特异性,精度,灵敏度(LOD和LOQ的评估),以及可重复性和矩阵干扰。 GC方法不适用于分析二苯基,二硅烷基和邻苯二甲酸二异癸酯,其在用于GC分离的条件下不够挥发性。此外,醇不应用作注射GC系统中样品的溶剂,以避免热注入端口中的酯交换。 GC中的单个四轴MS检测在E-液体中提供约1μg/ ml的敏感性,并且对于痕量邻苯二甲酸盐和对苯二甲酸酯的分析不足以敏感。与所有评估的方法相比,GC中的MS / MS检测提供了最佳的敏感性(E-液体中低于10ng / ml)。 LC足以分离所有评估的分析物。然而,与所有其他技术相比,LC中的UV检测不提供良好的灵敏度。 LC中的MS检测为对苯二甲酸酯提供了差的敏感性,但比其余的紫外线更好

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号