Abstract Reduction of interferences in the determination of lanthanides, actinides and transition metals by an octopole collision/reaction cell inductively coupled plasma mass spectrometer – Application to the analysis of Chios mastic
首页> 外文期刊>Talanta: The International Journal of Pure and Applied Analytical Chemistry >Reduction of interferences in the determination of lanthanides, actinides and transition metals by an octopole collision/reaction cell inductively coupled plasma mass spectrometer – Application to the analysis of Chios mastic
【24h】

Reduction of interferences in the determination of lanthanides, actinides and transition metals by an octopole collision/reaction cell inductively coupled plasma mass spectrometer – Application to the analysis of Chios mastic

机译:通过八孔碰撞/反应电池电感耦合等离子体质谱仪测定镧系元素,抗原和过渡金属中的干扰的干扰 - 应用于希俄斯乳香的分析

获取原文
获取原文并翻译 | 示例
           

摘要

Abstract Lanthanides, actinides and transition metals have demonstrated the ability to be used as fingerprint for the specification of the authenticity and geographical origin of food commodities. Therefore, the existence of analytical methods for their determination is of great importance, since both producers and consumers could benefit. An inductively coupled plasma mass spectrometric (ICP-MS) method was developed and validated for the determination of these elements in a Protected Designation of Origin product, the Chios mastic gum. A multivariate strategy for the microwave digestion of mastic was carried out. Five factors were studied and optimized. Hold time, temperature and HF volume, were found to be the most critical factors, so further optimization was performed. Molecular oxide (MO+, MO2 +) and hydroxide (MOH+) interferences were investigated. The capability of an octopole collision/reaction cell ICP-MS to attenuate or remove these interferences was studied. The effect of instrumental parameters on MO+/M+, MOH+/M+ and MO2 +/M+ ratios was studied to ensure that observed changes were a result of alteration of the parameter and not due to random fluctuations. Moreover, the effect of kinetic energy discrimination to suppress these species was demonstrated. The energy losses of ions were measured from stopping curves and the estimation of collision cross sections was done. Efficiencies of He and H2 gases were compared and H2 was finally selected for all elements. The calculated recoveries were ranged between 70 and 70% and 104% and the relative standard deviations (intermediate precision) were generally under 16%. The limits of detection were 0.07ngg?1 (Dy, Th) – 1.4ngg?1 (Ce). Graphical abstract Display Omitted Highlights ? A novel CRC-ICP-MS method was developed and validated for the determination of REEs in Chios mastic. ? A digestion procedure was proposed for the complete decomposition of complex matrices.
机译:<![cdata [ 抽象 镧系元素,滑动和过渡金属表明了用作粮食商品的真实性和地理来源的规范的指纹。因此,分析方法的确定是非常重要的,因为生产者和消费者都可以受益。开发了电感耦合等离子体质谱(ICP-MS)方法,并验证了在受保护的原产地产品,希俄斯乳香胶中测定这些元素。进行了乳香微波消解的多变量策略。研究和优化了五种因素。保持时间,温度和HF体积,被发现是最关键的因素,因此进行了进一步的优化。分子氧化物(Mo + ,mo 2 研究了+ )和氢氧化物(Moh + )干扰。研究了八孔碰撞/反应细胞ICP-MS的能力,以衰减或去除这些干扰。仪器参数对Mo + / m + ,moh + / m + 和mo 2 + / m + 比率,以确保观察到的变化是改变的结果参数而不是由于随机波动。此外,证明了动能辨别对抑制这些物种的影响。从停止曲线测量离子的能量损失,并进行碰撞横截面的估计。 HE和H的效率 2 气体被比较,H 2 最终选择所有元素。计算的回收率范围为70%至70%,104%,相对标准偏差(中间精度)通常不到16%。检测限为0.07 ng g ?1 (dy ,TH) - 1.4 NG G ?1 (CE) 。 图形抽象 显示省略< / ce:简单 - 段> 突出显示 开发了新的CRC-ICP-MS方法并验证了CHIOS Mastic的REES的确定。 提出了消化过程,以便完全分解复杂的复杂分解矩阵。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号