Quantitative measurement of carbon isotopic composition in CO2 gas reservoir by Micro-Laser Raman spectroscopy

机译:微激光拉曼光谱法定量测量CO2气体储层中的碳同位素组合物

获取原文
获取原文并翻译 | 示例
           

摘要

The use of Micro-laser Raman spectroscopy technology for quantitatively determining gas carbon isotope composition is presented. In this study, (CO2)-C-12 and (CO2)-C-13 were mixed with N-2 at various molar fraction ratios to obtain Raman quantification factors (F-12co2 and F-13co2). which provide a theoretical basis for calculating the delta C-13 value. And the corresponding values were 0.523 (0 C-12co2/C-N2 2) and 1.11998 (0 C-13co2/C-N2 1.5) respectively. It has shown that the representative Raman peak area can be used for the determination of delta C-13 values within the relative errors range of 0.076% to 1.154% in (CO2)-C-13/(CO2)-C-12 binary mixtures when F-12co2/F-13co2 is 0.466972625. In addition, measurement of delta C-13 values by Micro-Laser Raman analysis were carried out on natural CO2 gas from Shengli Oil-field at room temperature under different pressures. The delta C-13 values obtained by Micro-Laser Raman spectroscopy technology and Isotope Ratio Mass Spectrometry (IRMS) technology are in good agreement with each other, and the relative errors range of delta C-13 values is 1.232%-6.964%. This research provides a fundamental analysis tool for determining gas carbon isotope composition (delta C-13 values) quantitatively by using Micro-Laser Raman spectroscopy. Experiment of results demonstrates that this method has the potential for obtaining delta C-13 values in natural CO2 gas reservoirs. (C) 2018 Published by Elsevier B.V.
机译:提出了使用微激拉曼光谱技术来定量确定气体碳同位素组合物。在本研究中,(CO 2)-C-12和(CO2)-C-13以各种摩尔分数比混合,得到拉曼量化因子(F-12CO2和F-13CO2)。这为计算了ΔC-13值提供了理论依据。并且相应的值分别为0.523(0℃(0℃),分别为1.11998(0& C-13Co2 / c-N 2)。已经表明,代表性拉曼峰面积可用于测定(CO 2)-C-13 /(CO2)-C-12二元混合物中的0.076%至1.154%的相对误差范围内的ΔC-13值。当F-12CO2 / F-13CO2为0.466972625时。此外,通过在室温下在不同压力下在室温下从Shengli油田的自然CO 2气体进行微激光拉曼分析测量ΔC-13值。通过微激光拉曼光谱技术和同位素比质谱(IRMS)技术获得的ΔC-13值彼此吻合良好,并且δC-13值的相对误差范围为1.232%-6.964%。本研究提供了一种基本分析工具,用于定量使用微激激拉曼光谱定量测定气体碳同位素组合物(Delta C-13值)。结果的实验​​表明该方法具有获得天然CO2气体储层中的Delta C-13值的可能性。 (c)2018由elestvier b.v出版。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号