...
首页> 外文期刊>Journal of chromatography, A: Including electrophoresis and other separation methods >Calibration of nylon organic chemical integrative samplers and sentinel samplers for quantitative measurement of pulsed aquatic exposures
【24h】

Calibration of nylon organic chemical integrative samplers and sentinel samplers for quantitative measurement of pulsed aquatic exposures

机译:校准尼龙有机化学综合采样器和前哨采样器以定量测量脉冲水生暴露

获取原文
获取原文并翻译 | 示例
           

摘要

Environmental exposures often occur through short, pulsed events; therefore, the ability to accurately measure these toxicologically-relevant concentrations is important. Three different integrative passive sampler configurations were evaluated under different flow and pulsed exposure conditions for the measurement of current-use pesticides (n = 19), polyaromatic hydrocarbons (n = 10), and personal care products (n = 5) spanning a broad range of hydrophobicities (log Kow 1.5-7.6). Two modified POCIS-style samplers were investigated using macroporous nylon mesh membranes (35 pm pores) and two different sorbent materials (i.e. Oasis HLB and Dowex Optipore L-493). A recently developed design, the Sentinel Sampler (ABS Materials), utilizing Osorb media enclosed within stainless steel mesh (145 mu m pores), was also investigated. Relatively high sampling rates (Rs) were achieved for all sampler configurations during the short eight-day exposure (4300-27 mL/d). Under flow conditions, median Rs were approximately 5-10 times higher for POCIS-style samplers and 27 times higher for Sentinel Samplers, as compared to static conditions. The ability of samplers to rapidly measure hydrophobic contaminants may be a trade off with increased flow dependence. Analyte accumulation was integrative under pulsed and continuous exposures for POCIS-style samplers with mean difference between treatments of 11% and 33%; however, accumulation into Sentinel Samplers was more variable. Collectively, results show that reducing membrane limitations allows for rapid, integrative accumulation of a broad range of analytes even under pulsed exposures. As such, these sampler designs may be suitable for monitoring environmental substances that have short aquatic half-lives. (C) 2016 Elsevier B.V. All rights reserved..
机译:环境暴露通常是通过短暂的脉冲事件发生的。因此,准确测量这些毒理学相关浓度的能力很重要。在不同的流量和脉冲暴露条件下评估了三种不同的集成无源采样器配置,以测量广泛使用的当前使用的农药(n = 19),聚芳烃(n = 10)和个人护理产品(n = 5)疏水性(log Kow 1.5-7.6)。使用大孔尼龙网膜(孔径为35 pm)和两种不同的吸附剂材料(即Oasis HLB和Dowex Optipore L-493)研究了两个改进的POCIS型采样器。还研究了一种最新开发的设计,即Sentinel采样器(ABS材料),它利用封闭在不锈钢网孔(145微米孔径)中的Osorb介质。在短短八天的暴露时间内(4300-27 mL / d),所有采样器配置均获得了相对较高的采样率(Rs)。在流动条件下,与静态条件相比,POCIS型采样器的中值Rs约高5-10倍,而Sentinel采样器的中值Rs约高27倍。采样器快速测量疏水性污染物的能力可能会随着流量依赖性的增加而折衷。对于POCIS型采样器,在脉冲和连续暴露下,分析物的积累是综合的,处理之间的平均差为11%和33%。但是,积累到Sentinel采样器中的变量更多。总的来说,结果表明,减少膜的局限性使得即使在脉冲暴露条件下,也可以快速,全面地积累各种分析物。因此,这些采样器设计可能适合于监测具有短水生半衰期的环境物质。 (C)2016 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号