...
首页> 外文期刊>Journal of chromatography, A: Including electrophoresis and other separation methods >Correct assignment of lipophilic dye mixtures? A case study for high-performance thin-layer chromatography-mass spectrometry and performance data for the TLC-MS Interface
【24h】

Correct assignment of lipophilic dye mixtures? A case study for high-performance thin-layer chromatography-mass spectrometry and performance data for the TLC-MS Interface

机译:正确分配亲脂性染料混合物?高性能薄层色谱-质谱和TLC-MS接口性能数据的案例研究

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The TLC-MS Interface, the successor of the ChromeXtract, has been available for elution head-based coupling of high-performance thin-layer chromatography with mass spectrometry (HPTLC-MS) since 2009, and is meanwhile widespread in use, mainly for compound confirmation. Until now, quantitative performance data has not been reported in detail and thus were investigated in this study. The performance data of HPTLC electrospray ionization (ESI)-MS via the TLC-MS Interface showed good mean precisions (%RSD, n= 5) for 6 dyes in a commercially available dye mixture investigated at two different concentrations (7.3% for the 1:8 dilution, and 10.1% for the 1:16 diluted) in a selected worst case scenario. The respective mean precisions of absorbance measurements were <= 1.3%. For calibrations by HPTLC-ESI-MS, the mean determination coefficient was 0.9975 for the 6 dyes (versus 0.9997 for absorbance measurement). HPTLC-MS analysis revealed the incorrect assignment of components in two commercially available dye mixtures. Using an additional software (MassWorks) that delivered a 100 times increased mass accuracy, the proposal of molecular formulae was shown to be obtainable under certain conditions with a low resolution single quadrupole mass spectrometer and in the case of helpful information such as the double bond equivalents. This enabled the identification of the incorrectly assigned unknown dyes and clearly demonstrated the benefit of using HPTLC-MS for zone confirmation. (c) 2015 Elsevier B.V. All rights reserved.
机译:自2009年以来,TLC-MS接口(ChromeXtract的后继产品)已可用于基于洗脱头的高性能薄层色谱与质谱(HPTLC-MS)的偶联,同时已广泛使用,主要用于化合物确认。到目前为止,尚未详细报告定量性能数据,因此在本研究中进行了研究。通过TLC-MS接口进行的HPTLC电喷雾电离(ESI)-MS的性能数据显示,在两种不同浓度下对市售染料混合物中的6种染料(6种染料的浓度为7.3%),均具有良好的平均精度(%RSD,n = 5)在选定的最坏情况下,稀释度为8:1,稀释度为1:16则为10.1%。吸光度测量值的各自平均精度为<= 1.3%。对于通过HPTLC-ESI-MS进行的校准,这6种染料的平均测定系数为0.9975(吸光度测量为0.9997)。 HPTLC-MS分析表明,两种市售染料混合物中的组分分配不正确。使用附加的软件(MassWorks),其质量精度提高了100倍,表明分子式的建议在某些条件下使用低分辨率的单四极杆质谱仪是可行的,并且在诸如双键等效物等有用信息的情况下,也是可行的。 。这样就可以识别分配不正确的未知染料,并清楚地证明了使用HPTLC-MS进行区域确认的好处。 (c)2015 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号