Editorial Comments Clinically we know that laparoscopic surgeons routinely touch and dissect tissue with energy based cutting instruments without complication. I suspect we get away with this because the contact time at a specific point when bluntly pushing tissue with an ultrasonic shears or monopolar scissors is brief. Nevertheless, this article provides us with valuable knowledge. Ultrasonic energy instrumentation, ?whose advocates often claim it as the safest tool, actually has the greatest residual heat and can heat tissue more than 20C even 20 seconds after activation.
机译:社论评论临床上,我们知道腹腔镜外科医生通常会使用基于能量的切割工具来触摸和解剖组织,而不会造成并发症。我怀疑我们无法做到这一点,因为用超声波剪刀或单极剪刀直冲组织时在特定点的接触时间很短。但是,本文为我们提供了宝贵的知识。提倡超声波能量仪器的人经常声称它是最安全的工具,实际上具有最大的残留热量,即使在激活后20秒钟也可以加热组织超过20摄氏度。