首页> 外文期刊>Talanta: The International Journal of Pure and Applied Analytical Chemistry >Investigation of the new sorption preconcentration systems for determination of noble metals in rocks by inductively coupled plasma-mass spectrometry
【24h】

Investigation of the new sorption preconcentration systems for determination of noble metals in rocks by inductively coupled plasma-mass spectrometry

机译:电感耦合等离子体质谱法测定岩石中贵金属的新型吸附预富集系统的研究

获取原文
获取原文并翻译 | 示例
           

摘要

The reversible sorption preconcentration of noble metals (NMs) prior to their determination by inductively coupled plasma-mass spectrometry (ICP-MS) was investigated. Six new hypercrosslinked polystyrene sorbents were tested. The dependence of the degree of NMs sorption on the average degree of polymer network crosslinking and pore diameters was investigated. It was found that sorbents HP 10016, HP-300/6 and HP-500/6 have low efficiency of NMs chlorocomplexes extraction. Among Stirosorb sorbents (Stirosorb-2, Stirosorb-514 and Stirosorb-584) the highest efficiency of the extraction of NMs' chlorocomplexes has Stirosorb-514. Tributylamine (TBA), N-methylbenzylamine (MBA), N,N-dimethylbenzylamine (DMBA), N,N-dibenzylmetylamine (DBMA) were studied as the reagents for extraction of Ru, Rh, Pd, Ir, Pt and Au chlorocomplexes from hydrochloric acid solutions in the form of ion associates by reversed-phase mechanism. The reversible quantitative extraction of Ru, Pd, Pt and Au in system Stirosorb-514 - TBA - 1 M HCl in ethanol as eluent was achieved. It was found that resulting eluates do not contain matrix components which may cause spectral interferences on the stage of NMs determination by ICP-MS. The found scheme of NMs reversible sorption was validated by the analysis of certified reference materials of basic and ultrabasic rocks GPt-5, GPt-6 and SARM-7. Good agreement between the measured NMs concentrations and the certified values was demonstrated. The achieved limits of detection for Ru, Pd, Pt and Au vary within 10(-8)-10(-7) wt% range. (C) 2016 Elsevier B.V. All rights reserved.
机译:研究了通过电感耦合等离子体质谱法(ICP-MS)测定之前的贵金属(NMs)的可逆吸附富集。测试了六种新的超交联聚苯乙烯吸附剂。研究了NMs吸附程度对聚合物网络交联平均程度和孔径的依赖性。发现吸附剂HP 10016,HP-300 / 6和HP-500 / 6的NMs氯配合物萃取效率较低。在Stirosorb吸附剂(Stirosorb-2,Stirosorb-514和Stirosorb-584)中,提取NMs的氯配合物的最高效率是Stirosorb-514。研究了三丁胺(TBA),N-甲基苄胺(MBA),N,N-二甲基苄胺(DMBA),N,N-二苄基甲基胺(DBMA)作为从中提取Ru,Rh,Pd,Ir,Pt和Au氯配合物的试剂离子形式的盐酸溶液通过反相机理缔合。在乙醇溶液Stirosorb-514-TBA-1 M HCl中可逆定量萃取Ru,Pd,Pt和Au。发现所得洗脱液不包含可能在通过ICP-MS测定NMs的阶段引起光谱干扰的基质成分。通过对基本和超基本岩石GPt-5,GPt-6和SARM-7的认证参考材料进行分析,验证了发现的NMs可逆吸附方案。结果表明,测得的NMs浓度与认证值之间具有良好的一致性。 Ru,Pd,Pt和Au的检测极限在10(-8)-10(-7)wt%范围内变化。 (C)2016 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号