Fluorometric flow-immunoassay for alkylphenol polyethoxylates on a microchip containing a fluorescence detector comprised of an organic light emitting diode and an organic photodiode

机译:微芯片上的烷基酚聚乙氧基化物的荧光流动免疫测定,该芯片包含由有机发光二极管和有机光电二极管组成的荧光检测器

获取原文
获取原文并翻译 | 示例
       

摘要

A compact fluorescence detector was constructed on a microchip from an organic light emitting diode (OLED) as the light source and an organic photodiode (OPD) as the photo-detector and was used in an immunoassay for allcylphenol polyethoxylates (APE). The OLED based on a terbium complex emitted a sharp light at the main wavelength of 546 nm with a full width at half maximum of 9 nm. The incident photo-to-current conversion efficiency (IPCE) of the OPD fabricated with Fullerene 70(C-70) and tris[4-(5phenylthiopen-2-yephenyll-amine (TPTPA) was approximately 44% for light at a wavelength of 586 nm. The performance of the fluorescence detector was evaluated for the determination of resorufin (lambda(em)= 586 nm) and the photocurrent of the OPD due to the fluorescence of resorufin was proportional to the concentration of resorufin in the range from 0 to 18 mu M with a detection limit (S/N=3) of 0.6 mu M. The fluorescence detector was successfully utilized in a competitive enzyme-linked immunosorbent assay for APE, where an anti-APE antibody was immobilized on the surface of the channel of the Polydimethylsiloxane (PDMS) microchip or on the surface of magnetic microbeads. After an immunoreaction with a sample solution of APE containing a horse radish peroxidase (HRP)-labeled APE, the fluorescence of resorufin generated just after introduction of a mixed solution of Amplex Red and H2O2 was measured using the fluorescence detector. The calibration curve for the photocurrent signals of the OPD due to the fluorescence of resorufin against the logarithmic concentration of APE was sigmoidal in shape. The detection limits defined as IC80 were ca. 1 ppb and ca. 2 ppb, respectively, for the methods using the anti-APE antibody immobilized on the surface of the microchannel and in the case where the antibody was immobilized on the surface of magnetic microbeads. (C) 2014 Elsevier B.V. All rights reserved.
机译:紧凑型荧光检测器在微芯片上构建,由有机发光二极管(OLED)作为光源和有机光电二极管(OPD)作为光检测器,并用于免疫测定烯丙基酚聚乙氧基化物(APE)。基于b配合物的OLED在主波长546 nm处发出锐利的光,其半峰全宽为9 nm。用富勒烯70(C-70)和三[4-(5-苯硫基-2--2-苯基)-胺(TPTPA)制成的OPD的入射光电流转换效率(IPCE)大约为44%。 586 nm。评估了荧光检测器的性能,用于测定间苯二酚(lambda(em)= 586 nm),并且由间苯三酚的荧光引起的OPD的光电流与间苯三酚的浓度成正比,范围为0至18μM,检测限(S / N = 3)为0.6μM。该荧光检测器已成功用于APE的竞争性酶联免疫吸附测定,其中抗APE抗体固定在通道表面与含有辣根过氧化物酶(HRP)标记的APE的APE样品溶液进行免疫反应后,加入了Ampl的混合溶液后,产生了试卤灵的荧光使用荧光检测器测量红色和过氧化氢。由于间苯二酚的荧光相对于APE的对数浓度,OPD的光电流信号的校准曲线呈S形。定义为IC80的检出限为。 1 ppb和约。对于使用固定在微通道表面的抗APE抗体的方法以及在将抗体固定在磁性微珠表面的情况下,分别为2 ppb。 (C)2014 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号