PURPOSE: To evaluate the anatomic stability of an implanted Boston type I keratoprosthesis (KPro)-donor cornea interface and assess the presence or absence of a potential space (gap) between the KPro front plate and donor cornea using anterior segment optical coherence tomography (AS-OCT). The presence of a gap would raise concerns of a possible pathway for the exchange of extraocular fluid with the anterior chamber. METHODS: Fifteen eyes implanted with a Boston type I KPro were studied by the noncontact technique of AS-OCT (AC Cornea OCT prototype; OTI, Canada). All the KPro devices had been implanted at least 4 weeks before the study (mean: 7 months, range: 1-22 months). Eight eyes had aphakic Kpros, and the other 7 had pseudophakic implants. Anesthetized eyes were imaged before and during pressure application using sterile cotton-tip applicators. Pressure was applied for 10 seconds on the nasal or temporal side of the eye. Images were analyzed for any possible changes in the KPro-donor cornea interface during the application of pressure. RESULTS: Of 15 eyes, 10 had the threaded front plate model with a T-shaped silhouette and corrugated sides, whereas 5 had the threadless type with a T-shaped silhouette and smooth sides on cross-sectional optical coherence tomography. Of the 15 eyes, 2 revealed a gap between the front plate and the surface of the donor cornea. The rest revealed no gaps. With pressure, none of the eyes, including the 2 with gaps, demonstrated any change in the KPro-donor cornea interface during dynamic imaging (eg, gaping or evidence of fluid escape along the KPro-donor cornea borders). In all eyes, the position of the titanium locking ring was visible and verified to be in an adequate position. CONCLUSIONS: The implanted KPro-donor cornea interface seems to be stable dynamically using AS-OCT. A gap that has been documented with this imaging tool showed neither gaping nor escape of anterior chamber fluid during dynamic cross-sectional imaging. Further studies will be needed to assess the cause of these gaps and to determine if they are possibly related to the hydration status of the cornea, suture tension on the donor cornea, or other factors that remain to be determined.
机译:目的:使用前节光学相干断层扫描(AS)评估植入的波士顿I型角膜假体(KPro)-供体角膜界面的解剖稳定性,并评估KPro前板和供体角膜之间是否存在潜在的间隙(间隙)。 -OCT)。间隙的存在将引起对眼外液与前房交换的可能途径的关注。方法:采用AS-OCT(AC Cornea OCT原型; OTI,加拿大)的非接触式技术研究了十五只植入波士顿I型KPro的眼睛。在研究前至少4周植入了所有KPro设备(平均7个月,范围1-22个月)。 8眼有无晶状体Kpros,另7眼有假晶状体植入物。在使用无菌棉尖涂抹器施压之前和期间,对麻醉过的眼睛进行成像。在眼睛的鼻侧或颞侧施加压力10秒钟。在施加压力的过程中,分析了图像中KPro-供体角膜界面的任何可能变化。结果:在15只眼中,有10只眼的螺纹前板模型具有T形轮廓和波纹状侧面,而5只眼的无螺纹类型具有T形轮廓和光滑的侧面截面光学相干断层扫描技术。在15只眼中,有2只显示前面板和供体角膜表面之间存在间隙。其余显示没有差距。在压力下,在动态成像过程中,没有一只眼睛,包括两只有间隙的眼睛,都没有显示出KPro-供体角膜界面的任何变化(例如,沿KPro-供体角膜边界的缝隙或流体逸出的迹象)。在所有眼睛中,钛制锁紧环的位置均可见,并已验证其处于适当位置。结论:使用AS-OCT,植入的KPro-供体角膜界面似乎是动态稳定的。用此成像工具记录的间隙在动态横截面成像过程中既未显示前房积液也不漏出。需要进一步的研究来评估这些间隙的原因,并确定它们是否可能与角膜的水合状态,供体角膜上的缝合线张力或其他待确定的因素有关。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号