首页> 外文期刊>Electrochimica Acta >Voltammetric Studies of Cu(II) Ion Transfer Reaction with Picolinamide-phenylenevinylene across Liquid/liquid Interfaces and Their Sensing Applications
【24h】

Voltammetric Studies of Cu(II) Ion Transfer Reaction with Picolinamide-phenylenevinylene across Liquid/liquid Interfaces and Their Sensing Applications

机译:吡咯酰胺-亚苯基亚乙烯基跨液/液界面的铜(II)离子转移反应的伏安研究及其传感应用

获取原文
获取原文并翻译 | 示例

摘要

Voltammetric responses associated with the transfer reaction of Cu(II) cations assisted by picolinamide-phenylenevinylene (picolinamide-PV) across a polarized liquid/liquid interface were investigated and their sensing applications were demonstrated. The transfer process characteristics of Cu(II) ions by picolinamide-PV at the water/1,2-dichloroethane (1,2-DCE) interface was first investigated using cyclic voltammetry. The assisted transfer behavior of Cu(II) ions was then compared to that of Cu(I) ions. In order for Cu(II) ion selective sensing applications, a single microhole interface featuring the water and polyvinylchloride-1,6-dichlorohexane (PVC-1,6-DCH) gel layer incorporating picolinamide-PV was fabricated. The sensitivity for Cu(II) ions was improved by the use of differential pulse stripping voltammetry, which preconcentrates Cu(II) ions in the gel layer by means of holding the transfer potential of Cu(II) ions at 800 mV (vs. Ag/AgCl) for 20 s followed by stripping the ions from the gel to the aqueous phase. The Cu(II) ion sensor exhibited a low detectable concentration of 1 μM (0.13 ppm) Cu(II) ions alongside a linear dynamic range of 1 μM (0.13 ppm) to 50 μM (6.72 ppm) Cu(II) cations. An excellent selectivity over Ni~(2+), Ba~(2+) and Ca~(2+) ions was also achieved.
机译:研究了与吡啶甲酸酰胺-亚苯基亚乙烯基(picolinamide-PV)穿过极化液/液界面的Cu(II)阳离子转移反应相关的伏安响应,并证明了其传感应用。首先使用循环伏安法研究了吡啶甲酰胺-PV在水/ 1,2-二氯乙烷(1,2-DCE)界面上Cu(II)离子的转移过程特性。然后将Cu(II)离子的辅助转移行为与Cu(I)离子的辅助转移行为进行了比较。为了用于Cu(II)离子选择性传感应用,制造了一个具有水和聚甲基吡啶酰胺-PV的聚氯乙烯1,,6-二氯己烷(PVC-1,6-DCH)凝胶层的微孔界面。通过使用差分脉冲溶出伏安法提高了对Cu(II)离子的灵敏度,该方法通过将Cu(II)离子的转移电势保持在800 mV(vs. Ag)来预浓缩凝胶层中的Cu(II)离子。 / AgCl)20 s,然后将离子从凝胶中剥离到水相中。 Cu(II)离子传感器的可检测浓度为1μM(0.13 ppm)的Cu(II)离子,线性动态范围为1μM(0.13 ppm)到50μM(6.72 ppm)的Cu(II)阳离子。还获得了对Ni〜(2 +),Ba〜(2+)和Ca〜(2+)离子的优异选择性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号